PARAMETER MEASUREMENT INFORMATION
ethernet timing of RCV signals — no RXC
NO.
PARAMETER
MIN
TYP
MAX
UNIT
330
NORXC
Time with no clock pulse on RXC, when CRS is high (see Note 19)
2
µ
s
NOTE 19: If NORXC is exceeded local clock failure circuitry may become activated, resetting the device.
CRS ”1”
RXC
330
Figure 25. Ethernet Timing of RCV Signals — No RXC
ethernet timing of XMIT signals
NO.
PARAMETER
MIN
TYP
MAX
UNIT
340
HBWIN
Delay time from TXC high of the last transmitted data bit (TXEN is high) to COLL
sampled high, so not to generate a ”heart-beat” error
47
cycles
341
COLPUL
Minimum pulse duration of COLL high for guaranteed sample
20 ns + 1 cycle
ns
342
COLSET
Setup of COLL high to TXC high
20
ns
TXC
TXD
TXEN
COLL
340
341
342
Figure 26. Ethernet Timing of XMIT Signals