Setting Up the Hardware
EVM Hardware Setup
2-3
3) Verify that the EVM board’s SW3 boot/muxing configuration switch is
correctly set. The BM1, BM2, and BM3 switches should be set to On.
These switch settings, which are shown in the following figure,
enable the following:
■
SPI boot mode
■
EMIF A is 8-bit data bus for CS2
■
PCI pin multiplexing enabled on DM6467
■
DSP is booted via ARM processor
4) Connect the Ethernet cable to the Ethernet port on the EVM board
and to an Ethernet network port. Note that the U-Boot bootargs must
include "ip=dhcp" to enable the network connection.