9.4 Device Functional Modes
Table 9-10. Modes and Functions
FUNCTION
READY (PRIOR
TO I
2
C) AND
AFTER RESET
HOST MODE
READY (AFTER
I
2
C)
CHARGE
SHIP MODE
HIGH_Z
ACTIVE
BATTERY
VOVP
Yes
Yes
Yes
No
No
No
VUVLO
Yes
Yes
Yes
Yes
Yes
Yes
VBATUVLO
Yes
Yes
Yes
No
Yes
Yes
VINDPM
Default or
registers
Default or
registers
If enabled
No
No
No
SYS
Default or
registers
Default or
registers
If enabled
No
If enabled
If enabled
LS/LDO
Default or
registers
Default or
registers
If enabled
No
If enabled
If enabled
BATFET
Yes
Yes
Yes
No
Yes
Yes
TS
Yes (VIN Valid)
Yes (VIN Valid)
Yes
No
No
No
IPRETERM
External
Default, registers,
or external
Default, registers,
or external
No
No
No
ISET
External
Default, registers,
or external
Default, registers,
or external
No
No
No
ILIM
External
Default, registers,
or external
Default, registers,
or external
No
No
No
MR input
Yes
Yes
Yes
Yes
Yes
Yes
LSCTRL input
Yes
Yes
Yes
No
Yes
Yes
RESET output
Yes
Yes
Yes
No
Yes
Yes
INT output
Yes
Yes
Yes
No
No
Yes
I
2
C interface
Yes
Yes
Yes
No
No
Yes
CD input
Yes
Yes
Yes
No
Yes
Yes
PG output
Yes
Yes
Yes
No
No
If enabled
VBMON
No
Yes
No
No
No
Yes
Table 9-11. Fault and Status Condition Responses
FAULT or STATUS
ACTIONS
CHARGER
BEHAVIOR
SYS BEHAVIOR
LS/LDO
BEHAVIOR
TS BEHAVIOR
VIN_OV
Update VIN_OV status,
Update STAT to fault, interrupt
on INT, PG shown not good
Disabled
Enabled through
BAT
Enabled through
BAT
Disabled
VIN_UV
Update VIN_UV status, Update
STAT to fault, interrupt on INT,
PG shown not good
Disabled
Enabled through
BAT
Enabled through
BAT
Disabled
VIN_ILIM
Update charge in progress
status, interrupt on INT, input
current is limited
Enabled, input
current limited
Enabled (if enabled) Enabled (if enabled)
Enabled
OVER_TEMP
Disabled
Disabled
Disabled
Disabled
BAT_UVLO
Update BAT_UVLO status,
Update STAT to fault, interrupt
on INT
Pre-charge
Enabled (if enabled)
and VIN Valid
Enabled (if enabled)
and VIN Valid
Enabled if VIN Valid
SW_SYS_SHORT
Enabled
Current Limit
Enabled (if enabled)
Enabled
LS_LDO_OCP
Enabled
Enabled (if enabled)
Current Limit
Enabled
TIMER fault
Update TIMER, Update STAT
to fault, interrupt on INT
Disabled
Enabled (if enabled) Enabled (if enabled)
Disabled
VINDPM
Update VINDPM_STAT,
Update STAT to fault, interrupt
on INT
Enabled, input
current reduced
Enabled (if enabled) Enabled (if enabled)
Enabled
SLUSCZ6A – JANUARY 2018 – REVISED MAY 2021
Copyright © 2021 Texas Instruments Incorporated
29
Product Folder Links: