40
Error Data List
5.7.5 PASS/FAIL Commands (While The Lid is Closed)
PASS
A command that demonstrates what happens if the DUT passes a test.
If the PASS command is sent, the PASS LED on the control box will glow green (
), and the lid
will open automatically.
Type
Command
Input
PASS
Response
{ OK | ERR40 }
●
OK : turns the green PASS LED on, and the lid opens.
●
ERR40: Status Error, The command is sent while the lid is open.
FAIL
A command that demonstrates what happens if the DUT fails a test.
The FAIL LED on the control box will glow red (
), and the lid will
NOT
open.
Type
Command
Input
FAIL
Response
{ OK | ERR40 }
●
OK : turns the red FAIL LED on.
●
ERR40: Status Error. The command is sent while the lid is open.