I/O Interface Panels
13
I/O Interface
Oder Number
Transmission Speed / Line
Voltage
*Typical Shielding
USB 2.0 Filter
3409-0018A-3
480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz
USB 3.0 Filter(Active)
3409-0042A-2
5 Gbps / 5 V, 600 mA /
Max Current: 1.5 A
>80 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>75 dB from 3 to 6 GHz
RJ-45 Filter
3409-0022A
1 Gbps Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz
DC Power Adaptor,
3406-0004A
50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz
DC Power Adaptor,
Banana Jack Type
3406-0004A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz
AC Power Adaptor
3103-0009A
250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz
1. Shielding effectiveness is an estimated value with each I/O interface applied.
2. The data above was measured by TESCOM, and they may be different depending on the
measuring method and environment.
3. Each shielding effectiveness is measured without according cable. It is likely affected when a
cable is connected. Also, it may vary depending on the type of cable.
Summary of Contents for TC-5910DP
Page 1: ...TC 5910DP Pneumatic Shield Box User Manual R20191023...
Page 9: ...PART 1 1 Getting Started...
Page 13: ...PART 2 5 Hardware Description...
Page 17: ...Dimensions 9 2 2 Dimensions 2 2 1 Outer Dimensions...
Page 18: ...10 Dimensions 2 2 2 Inner Dimensions...
Page 23: ...PART 3 15 Putting into Operation...
Page 49: ...PART 4 41 Maintenance...
Page 57: ...Expendables and Accessories 49 Figure 7 1 TC 5910DP Expendables Location...