Melody 2 Hydraulic MK2 Installation Manual - Issue f
CARRIAGE RESYNC TIMER
TIMER MODE J - 3 MINUTES
Carriage Resync Timer Operation
When the lift arrives at and remains at the lower level and
the gate is opened and closed the Carriage Resync Timer is
activated. After approximetely 3 minutes of inactivity this time
outputs a 5V pulse for 1 second on the DNsig of the lift. This
causes the control ciruit to enrige the solenoid valve of the
lift for 1 Second. This ciruit is protected by a safety linit swith
that is only operational when the lift is at the lower level.