Wiring
ED20112F 13/05/2010
General Information
The CE1466 board provides the main controller unit for the Melody Hydraulic Lift
and is located in an IP65 rated Painted Steel Box installed externally from the lifting
platform.
The Control Box is connected to the Lift Carriage by two “Extra-Flex“ 7 core trailing
cables, and in conjunction with a DC/DC Converter, two timer units, and various
safety switches comprise the total control circuitry for the lift.
Mains Voltage is supplied to the PCB within the control box via a Flexible cable
from a RCD unit within the buildings consumer unit, via a 10A mains Filter located
in the Upper Right Hand Side of the Control Box to the CE1466 board.
AC is provided to the External Pump Unit via a Flexible mains cable connected
directly for the pump outputs of the CE1466 board. Similarly the pumps pressure
switch and solenoid unit connect to the Control Box via a single 4-core cable.
Battery Backup for use in a power loss situation is provided by a 12V 7Ah
rechargeable Sealed Lead-Acid Battery.
Interconnections for the External Call Stations and upper level gates are provided
from within the Control Box. The Platform Gate, Control Stations and Safety
Switches are connected on the lift carriage by means of a loom to the “Extra Flex”
7 Core Trailing Cables.
Definition of Abbreviations
Colours
Others
BK
Black
SCCB
Safety Control Circuit Board
BN
Brown
CE1651
SCCB
R
Red
CE1466
Top Controller
O
Orange
TSE
Top Safe Edge
Y
Yellow
DSE
Down Safe Edge
BL
Blue
UPHLD
Up Hold
V
Violet
DNHLD
Down Hold
GN
Green
P
Pink
Y/G
Yellow/Green Striped UPSIG
Up Signal
W
White
DNSIG
Down Signal
G
Grey
S/E
Safe Edge
W/BK
White/Black Striped
LMT
Limit
LGE
Lower Gate Enable
UGE
Upper Gate Enable
W/R
Wire/Red Striped
SW
Switch
Wiring Layout:
See Fig 2: Control Box Wiring (pg 33) & Fig3: Car Wiring (pg 34).
NOTES
Summary of Contents for Melody 2 hydraulic MK2
Page 35: ...35 Melody 2 Hydraulic MK2 Installation Manual Issue f FIG 3 CARRIAGE WIRING...
Page 36: ...36 Melody 2 Hydraulic MK2 Installation Manual Issue f FIG 4 CONTROL SYSTEM COMPLETE WIRING...
Page 42: ...42 Melody 2 Hydraulic MK2 Installation Manual Issue f...
Page 48: ...48 Melody 2 Hydraulic MK2 Installation Manual Issue f...
Page 50: ...50 Melody 2 Hydraulic MK2 Installation Manual Issue f...
Page 54: ...54 Melody 2 Hydraulic MK2 Installation Manual Issue f...
Page 58: ...58 Melody 2 Hydraulic MK2 Installation Manual Issue f ED20431 23 08 2011 Bulletins...
Page 60: ...60 Melody 2 Hydraulic MK2 Installation Manual Issue f...