ATTENTION! Don't use alcohol-containing means, benzene, kerosene and other highly inflammable
matters for ignition. Don't use a glossy paper, trimmings of wood particle boards, laminated flooring board,
orgalite because these matters would evolve noxious substances under burning, and would be cause of
outburst and damage of a stove.
ATTENTION! Don't use the stove with an empty heat exchange unit and a hot-water tank or an
unconnected system of water heating (if available).
ATTENTION! Don't use the stove inappropriately.
ATTENTION! Don't use the stove in autohouses, trailers and tents.
ATTENTION! Don't commit overheating of the stove at the time of its operation.
ATTENTION! At the time of the first heating of the stove applied on the metal industrial oils and light
volatile compounds of organosilicone enamel evolve smoke and smell, which aren't evolved in the
following.
ATTENTION! Don't make mechanical action to a surface of a stove till complete cooling and final
polymerization of paint at the time of the first heating in order to avoid damage of a lacquer coating.
ATTENTION! The first heating of the model «Vitra» shall be carried out with opened door of combustor to
prevent smoked translucent screen.
n
Doesn't have external damages of a carcass.
n
A door freely revolves on hinges, closely adjoins to a carcass and is efficiently fixed by a lock.
n
A translucent screen on a door (if available) doesn't have damages.
n
Fire bar is safe without burnouts and cracks.
n
An ash drawer has to freely move and it closely adjoins to a carcass in the closed position.
n
A heat exchange unit (if available) doesn't have any damages.
Overheating of the stove can be identified by red glow of the metal in the dark.
This situation can appear upon the uncontrolled air supply into the fire box. For example, when the door is
open. The stove warming up may lead to dangerous conditions of the stove operation and its premature breakdown.
People having chest troubles and owners of the pets susceptible to smoke (for example birds) should take
precaution measures.
The first heating of the stove it is necessary making open-air with fire prevention discipline, at least one hour,
with charging of a fire box in half in the regime of active combustion.
For right operation of the stove, at the time of the first heating it is necessary to organize a temporary flue with
height at least 2m.
For the model of stove with built-in heat exchange unit it is necessary to organize temporary water heating
system during the first pre-heating.
Please, make sure in normal functioning of the all components of the stove and protective constructions. A
faulty stove is not permitted to operation.
An efficient stove:
It is necessary to load special stones into stones section. The manufacturer recommends using gabbrodiabase,
peridotite, talcum peach, jadeite. These volcanic rocks possess a beautiful pattern and composed of durable minerals
against physical and chemical action. Also, these volcanic rocks don't contain harmful impurities. These volcanic
rocks possess considerable heating capacity, stand against large, repeated temperature differential. Also, stones are
fireproof and don't break. Irregular shape of stones and difference of its sizes provide maximum filling of stones
section and maximal area of heat output.
9.2. Commissioning of the stove
9.3. Stones for stones section
33