![TermaCook Integral 800 Instructions For Fitting And Use Download Page 44](http://html1.mh-extra.com/html/termacook/integral-800/integral-800_instructions-for-fitting-and-use_1089126044.webp)
GB
44
Terma
Cook
Installation of the hob fan
· The product may only be connected by an authorised quali-
fied technician in compliance with applicable local regula-
tions. The same applies for the exhaust connections. The fitter is
responsible for perfect functioning at the installation location.
· When carrying out installation work, please observe the
relevant Building Regulations of the states and the energy
supply companies.
· The hob fan can be operated in the extraction air and
recirculation air mode.
· Lead the outgoing air outside through a ventilation shaft
intended for this purpose or through the wall of the building.
· The outgoing air may not be lead into a smoke or exhaust gas
chimney that is in use. If in doubt, please consult the district
master chimney sweep.
· If a fireplace requiring a chimney (coal, wood, oil or gas firing)
is used in the environment of the hob fan, you will need to
ensure that there is a sufficient supply of inlet air, otherwise a
risk of poisoning will arise. Operation of the hob fan will be safe
provided that the negative pressure caused by the hob fan
does not exceed 0.04 mbar (4 Pa) and that sufficient inlet air
can flow into the room.
· Exhaust air ducts must comply with fire class B 1 DIN 4102.
Please make sure that the minimum nominal diameter of the
appliance connections is not reduced.
· The Naber Compair Flow 150 system which is recommended
for the air flow and is compatible with the hob extractor should
always be used.
· The nominal diameter of the circulating air pipes may not be
less than 150 mm.
· Exhaust pipes should be very short with wide curves (no 90°
curves) and no reduction of the diameter.
· Always use pipes with a diameter of not less than 150 mm.
Elbows/bends may not be installed closer than 50 cm in front
of the fan module. Always insert a straight piece of approx.
50 cm between two bends/elbows.
· The cross-section of wall vents and the cut-out in the base
panel should at least correspond to the exhaust air duct.
An outflow opening of at least 300 cm² must be given. Shorten
the height of the skirting board or drill corresponding holes.
· During installation, make sure that the convection air unit
remains accessible when the kitchen has been completely
mounted. This means that the levelling feet of the kitchen units
will need to be repositioned if necessary.
Electrical connection
· The electrical connection must be carried out by a qualified
electrician who is authorised to carry out such work!
· Statutory regulations and the connection specifications issued
by the local power supply company must be strictly observed.
· When connecting the appliance it must be ensured that there
is a device which makes it possible to disconnect it from the
mains at all poles with a contact opening width of at least
3 mm. Line-protecting switches, fuses o r contactors are suitab-
le cut-out devices.
When connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
· The earth wire must be sufficiently long so that if the strain relief
fails, the live wires of the connecting cable are subjected to
tension before the earth wire.
· Any superfluous cable must be removed from the installation
area beneath the appliance.
· Make sure that the local mains voltage is the same as the
voltage on the rating label.
· Full protection against accidental contact must be ensured on
installation.
· Attention: Incorrect connection may result in the power
electronics unit being destroyed.
Power supply
Mains voltage: 380-415V 3N~, 50/60Hz
Component rated voltage: 220-240V
Mains cable available in the factory
· The hob has been fitted with a temperature-resistant connection
cable in the factory.
· Connection to the mains is carried out in accordance with the
circuit diagram, unless the connection cable is already fitted
with a plug.
· If the mains cable of this appliance is damaged it will need to
be replaced with a special connection cable. In order to
avoid any risks, this must be carried out by the manufacturer or
his Customer Service.
Electrical connections
schw
arz
br
aun
gr
au
w
eiß
blau
grün-gelb
grün-gelb
schw
arz
br
aun
gr
au
w
eiß
blau
grün-gelb
grün-gelb
Instructions for assembly