Power boost setting
The power boost setting makes additional power available for in-
duction cooking zones. A large quantity of water can be brought
to the boil very quickly. The power boost setting operates for 5
minutes, after which the power level is automatically reduced to
power setting 9.
1. Switch on the hob.
2. Then press a cooking zone selection key (e.g.
for back).
The selected power setting display will light up brightly.
3.
Press the Minus key
once in order to set the highest
power setting 9.
4.
Press the Plus key
once in order to activate the power
boost setting. The power display will show a P.
5. After 5 minutes the power boost setting will switch off au-
tomatically. The P will go off and the power level will switch
down to 9.
Power management
For technical reasons two cooking zones always comprise a mo-
dule and have a maximum power level.
If this power range is exceeded when a higher power setting level
or the power boost function is switched on the power manage-
ment system will reduce the power setting of the corresponding
cooking zone of the module.
The display for this cooking zone will initially blink, after which the
highest- possible power setting will be consistently displayed.
Important
Press the minus key to prematurely de-activate the power setting.
Attention.
Risk of overheating!
Do not heat up any oil/frying fat
with the ower boost setting.
Bridging function (if available)
The front and the rear cooking zones may be activated together
for a cooking process (bridging function). This enables larger
cookware to be used.
1. Switch on the hob.
2. Press the
rear
and the
front
cooking zone selection
key
simultaneously to activate the bridging function.
The bridging function is activated, the symbol
appears
.
Operation is carried out with the
Minus key
and the
Plus key
of the front cooking zone.
3. To deactivate press the two
cooking zone selection keys
simultaneously again or switch off the hob.
Important
The roaster or the pot will need to cover at least half of the cook-
ing zones used in order to be recognised by the pan recognition
device!