July 2020
Part No. 1297714GT
Z
®
-45 DC • Z
®
-45 FE
71
Service and Repair Manual
Control System Fault Codes
Error Source
Error Type
Cause
Effect
Solution
ID
Component
ID
Name
21
Primary Up/Down
Joystick
11
Shorted to
supply
5V
Primary Boom Disabled
Verify:
*5V at JC7-2
(P162PJW OR)
*B- at JC7-1 (JSGND
BR)
*500 to 4500 mV at
JC7-3 & PCON
C46-11 (C195STC BL/
WH) through joystick
motion.
16
Sensor at Zero
0V
17
Not calibrated
Not between 2000
& 3000 mV at
startup
22
Primary Up Valve
25
Resistance Too
High
Open Circuit or
Ohms > 60
Associated Function
disabled
*Check Ohms
*Verify no open/short
circuit across
PCON C20-5 BK & B-
(V01PBU RD)
26
Resistance Too
Low
Short or
Ohms <5
23
Primary Down Valve
25
Resistance Too
High
Open Circuit or
Ohms > 60
Associated Function
disabled
*Check Ohms
*Verify no open/short
circuit across
PCON C20-6 BK & B-
(V02PBD RD/BK)
26
Resistance Too
Lowt
Short or
Ohms <5
24
Primary Boom Angle
Sensor
11
Shorted to
supply
>4850 mV
Act as if in Out of
Stowed
position
*elevated drive speed
*no elevated drive due
to
tilt drive cutout on CE
units
Driving at 2 MPH is
allowed if primary and
secondary
angle sensors are
calibrated
and the mV value is
close to the calibrated,
stowed value.
Verify:
*5V from C27-5 to
C12-C (P109PWR GR/
WH)
*B- at Pin C12-A
*Signal Output
approximately 1000 -
4000 mV across range
of motion at
LRDCON C27-16
(C123 PBS RD/BK)
*Cycle Power with
problem
corrected to clear fault
To Calibrate:
*Stowed mV must be
between 2600 & 3400
mV
*Elevated mV must be
between 400
16
Sensor at Zero
0V
17
Not calibrated
Calibration Not
Completed
19
Out of Range
Reported angle
sensor value out
outside normal
range more than 3
degrees
26
Primary Extend
Valve
25
Resistance Too
High
Open Circuit or
Ohms > 60
Associated Function
disabled
*Check Ohms
*Verify no open/short
circuit across
TCON C20-3 BK & B-
(V07PBE BK)
26
Resistance Too
Low
Short or
Ohms <5
Control System Fault Codes
Summary of Contents for Genie Z-45 DC
Page 121: ...July 2020 Service and Repair Manual 111 Wiring Diagram Options ...
Page 124: ...July 2020 Service and Repair Manual 114 Wiring Diagram Options ...
Page 125: ...July 2020 Service and Repair Manual 115 Schematics Options DC and FE Models ...
Page 127: ...July 2020 Service and Repair Manual 117 Power Cable Wiring Diagram ...
Page 129: ...July 2020 Service and Repair Manual 119 Hydraulic Schematic ...
Page 131: ...July 2020 Service and Repair Manual 121 Electrical Schematic DC FE Models ...
Page 134: ...July 2020 Service and Repair Manual 124 Electrical Schematic DC FE Models ...
Page 136: ...July 2020 Service and Repair Manual 126 Electrical Schematic DC FE Models ...