Note: When removing a hose assembly or fitting,
the O-ring (if equipped) on the fitting and/or hose
end must be replaced. All connections must be
torqued to specification during installation. Refer to
Specifications,
Hydraulic Hose and Fitting Torque
Specifications.
1 Locate the hydraulic tank valve at the hydraulic
tank. Close the valve.
NOTICE
Component Damage hazard.
Do not perform any functions
with hydraulic tank shut off valve
closed. Remove the key switch
and tag the machine to inform
personnel of the condition.
2 Tag, disconnect and plug function pump
hydraulic hoses. Cap the fittings on the pump.
WARNING
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
3 Support the pump with a suitable lifting device.
4 Remove the pump mounting bolts. Carefully
remove the pump.
NOTICE
Component damage hazard. Be
sure to open the hydraulic tank
valve and prime the pump after
installation.
Hydraulic Pumps
Summary of Contents for Genie Z-45 DC
Page 121: ...July 2020 Service and Repair Manual 111 Wiring Diagram Options ...
Page 124: ...July 2020 Service and Repair Manual 114 Wiring Diagram Options ...
Page 125: ...July 2020 Service and Repair Manual 115 Schematics Options DC and FE Models ...
Page 127: ...July 2020 Service and Repair Manual 117 Power Cable Wiring Diagram ...
Page 129: ...July 2020 Service and Repair Manual 119 Hydraulic Schematic ...
Page 131: ...July 2020 Service and Repair Manual 121 Electrical Schematic DC FE Models ...
Page 134: ...July 2020 Service and Repair Manual 124 Electrical Schematic DC FE Models ...
Page 136: ...July 2020 Service and Repair Manual 126 Electrical Schematic DC FE Models ...