Pump efficiency is calibrated automatically but
must be verified after a new pump installation and
before performing any boom speed calibrations.
Refer to Repair Procedures,
Calibration Process
Steps
. This procedure determines the number
of revolutions that are required to create a
determined amount of flow.
Note: Start this procedure with the secondary
boom in the stowed position and primary boom
at or above horizontal. Position the machine in
a suitable location with sufficient vertical space.
Refer to Navigation Menus,
Settings Menu
.
Note: Primary and secondary angle sensors must
be functional and calibrated. Refer to Repair
Procedures,
How to Calibrate Booms Angle
Sensors
.
1 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
Note: If the unit is equipped with the engine option,
set the machine to DC mode.
2 Move and hold the drive enable toggle switch
in the right direction while holding steer in the
right direction.
3 When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer joystick.
4 Momentarily activate steer in the right direction
until SETTINGS is shown on the display.
5 Momentarily activate the drive enable toggle
switch in the right direction until you see the
VALVE AND SENSOR SETTINGS screen.
6 Momentarily activate the drive enable toggle
switch in the right direction until CALIBRATE
TILT SENSOR is shown on the display.
7 Continue to momentarily active the steer in
the right direction until PUMP EFFICIENCY
CALIBRATION is shown on the display.
8 Momentarily activate the drive enable
toggle switch to enter PUMP EFFICIENCY
CALIBRATION menu.
9 Fully elevate the secondary boom.
10 Fully lower the secondary boom.
Result: A one second pulse alarm will sound
indicating a successful pump efficiency
calibration. The display will indicate pump
efficiency in %.
To exit programming mode:
11 Move and hold the drive enable toggle in the
left position until the display returns to SYSTEM
READY mode.
Hydraulic Pumps
Summary of Contents for Genie Z-45 DC
Page 121: ...July 2020 Service and Repair Manual 111 Wiring Diagram Options ...
Page 124: ...July 2020 Service and Repair Manual 114 Wiring Diagram Options ...
Page 125: ...July 2020 Service and Repair Manual 115 Schematics Options DC and FE Models ...
Page 127: ...July 2020 Service and Repair Manual 117 Power Cable Wiring Diagram ...
Page 129: ...July 2020 Service and Repair Manual 119 Hydraulic Schematic ...
Page 131: ...July 2020 Service and Repair Manual 121 Electrical Schematic DC FE Models ...
Page 134: ...July 2020 Service and Repair Manual 124 Electrical Schematic DC FE Models ...
Page 136: ...July 2020 Service and Repair Manual 126 Electrical Schematic DC FE Models ...