4-26
Z
®
-33/18
Part No. 1268514GT
January 2020
Section 4 • Fault Codes
Error Source
Error Type
ID
Component
ID
Name
Cause
Effect
Solution
205
Drive Power
Contactor
26
VALUE TOO
LOW
Coil Shorted
All functions
disabled
*Check connections
between right motor
controller and contactor
coil.
*Check diode on main
contactor. If OK replace
contactor or right AC
motor controller if
contactor is OK
12
VALUE TOO
HIGH
Contacts
detected closed
when contactor
not commanded
*Check for voltage at
main contactor coil
with machine in the ON
position. (24V DC on
red wire. 48V DC on
orange wire)
*Replace main
contactor.
13
VALUE TOO
LOW
Contacts Stuck
Open
(won't
close when
commanded)
*Check for voltage at
main contactor coil
with machine in the on
position. (24V DC on red
wire. 48V DC on orange
wire)
*Replace main
contactor.
CONTROL SYSTEM FAULT CODE CHART
Summary of Contents for Genie Z-33/18
Page 6: ...vi Z 33 18 Part No 1268514GT January 2020 This page intentionally left blank ...
Page 12: ...xii Z 33 18 Part No 1268514GT January 2020 This page intentionally left blank ...
Page 104: ...5 2 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Electrical Symbols Legends ...
Page 105: ...January 2020 Part No 1268514GT Z 33 18 5 3 Section 5 Schematics Hydraulic Symbols Legends ...
Page 106: ...January 2020 Section 5 Schematics 5 4 5 5 Electrical Schematic ...
Page 108: ...January 2020 Section 5 Schematics 5 7 Electrical Schematic ...
Page 110: ...January 2020 Section 5 Schematics 5 9 Electrical Schematic ...
Page 112: ...January 2020 Section 5 Schematics 5 11 Electrical Schematic ...
Page 114: ...January 2020 Section 5 Schematics 5 13 Electrical Schematic ...
Page 117: ...5 16 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Hydraulic Schematic ...