4-22
Z
®
-33/18
Part No. 1268514GT
January 2020
Section 4 • Fault Codes
Error Source
Error Type
ID
Component
ID
Name
Cause
Effect
Solution
190
AC_R_MOTOR
AC Motor Right
Side
12
VALUE TOO
HIGH
Motor Windings
Open or
Resistance is
Too High
Drive
disabled.
Main Lift
Functions
Allowed
*Do not operate machine
with batteries charging.
*Check for loose motor
cable connections.
*Check for 33V AC
across 2 motor lugs
when joystick fully
deflected.
*Replace right drive
motor
*Replace right AC motor
controller
15
VALUE TOO
LOW
Motor Windings
Shorted
Drive
Disabled.
Functions
allowed.
*Do not operate machine
with batteries charging.
*Check for shorted motor
cable connections.
*Check for 33V AC
across 2 motor lugs
when joystick fully
deflected.
*Replace right drive
motor
*Replace right AC motor
controller
21 FAULT
Temperature or
speed sensor
failure
Drive
Current
Reduced to
50%
*Check wires to thermal/
speed sensor at 6 pin
Deustch connector C17
on motor.
*Check thermal sensor
resistance.
CONTROL SYSTEM FAULT CODE CHART
Summary of Contents for Genie Z-33/18
Page 6: ...vi Z 33 18 Part No 1268514GT January 2020 This page intentionally left blank ...
Page 12: ...xii Z 33 18 Part No 1268514GT January 2020 This page intentionally left blank ...
Page 104: ...5 2 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Electrical Symbols Legends ...
Page 105: ...January 2020 Part No 1268514GT Z 33 18 5 3 Section 5 Schematics Hydraulic Symbols Legends ...
Page 106: ...January 2020 Section 5 Schematics 5 4 5 5 Electrical Schematic ...
Page 108: ...January 2020 Section 5 Schematics 5 7 Electrical Schematic ...
Page 110: ...January 2020 Section 5 Schematics 5 9 Electrical Schematic ...
Page 112: ...January 2020 Section 5 Schematics 5 11 Electrical Schematic ...
Page 114: ...January 2020 Section 5 Schematics 5 13 Electrical Schematic ...
Page 117: ...5 16 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Hydraulic Schematic ...