18 Press and hold a function enable/speed select
button and the platform level down button until
the digital level displays approximately 34 ±
2 degrees.
19 At the ground controls, press the
plus
button
or
minus
button to adjust the display to the
exact value shown on the digital level and
press the
enter
button.
Note: If the measured angle already matches the
angle shown on the display at the ground controls,
press the
plus
button or
minus
button to change
the angle and then change back to the measured
value. The system must detect a change in
displayed value to record the calibrated value.
20 Press and hold a function enable/speed select
button and the platform level down button until
the digital level displays approximately 8 ±
2 degrees.
21 At the ground controls, press the
plus
button
or
minus
button to adjust the display to the
exact value shown on the digital level and
press the
enter
button.
Note: If the measured angle already matches the
angle shown on the display at the ground controls,
press the
plus
button or
minus
button to change
the angle and then change back to the measured
value. The system must detect a change in
displayed value to record the calibrated value.
22 Press and hold a function enable/speed select
button and raise the jib boom above horizontal
to provide additional ground clearance for the
remaining calibration points.
23 Press and hold a function enable/speed select
button and the platform level down button until
the digital level displays approximately 18 ±
2 degrees.
Calibration angles
24 At the ground controls, press the
plus
button
or
minus
button to adjust the display to the
exact value shown on the digital level and
press the
enter
button.
Note: Be sure the number entered at the ground
controls is a negative number.
Note: If the measured angle already matches the
angle shown on the display at the ground controls,
press the
plus
button or
minus
button to change
the angle and then change back to the measured
value. The system must detect a change in
displayed value to record the calibrated value.
Summary of Contents for Genie Z-135/70
Page 14: ......
Page 37: ...October 2018 Service and Repair Manual Specifications Part No 1268557GT Z 135 70 23 T ...
Page 135: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 121 ...
Page 137: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 123 ...
Page 139: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 125 ...
Page 141: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 127 ...
Page 147: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 133 ...
Page 153: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 139 ...
Page 155: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 141 ...
Page 159: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 145 ...
Page 161: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 147 ...
Page 233: ...October 2018 Service and Repair Manual 219 Generator Wiring Schematic ...
Page 236: ...Service and Repair Manual October 2018 222 Hydraulic Generator Welder Option ...
Page 242: ...Service and Repair Manual October 2018 228 Hydraulic Schematic from serial number 535 ...
Page 244: ......