Service and Repair Manual
October 2018
Manifolds
150
Z®-135
/70
Part No. 1268557GT
8-14
Valve Coils
How to Test a Coil
A properly functioning coil provides an
electromotive force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil that provides this force field.
Since coil resistance is sensitive to temperature,
resistance values outside specification can produce
erratic operation. When coil resistance decreases
below specification, amperage increases. As
resistance rises above specification, voltage
increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
1
Tag and disconnect the wiring from the coil to
be tested.
2
Test the coil resistance.
Result: The resistance should be within
specification, plus or minus 30%.
Result: If the resistance is not within
specification, plus or minus 30%, replace the
coil.
Valve Coil Resistance
Specification
Note: The following coil resistance specifications
are at an ambient temperature of 68°F / 20°C. As
valve coil resistance is sensitive to changes in air
temperature, the coil resistance will typically
increase or decrease by 4% for each 18°F / 10°C
that your air temperature increases or decreases
from 68°F / 20°C.
Valve Coil Resistance Specification
Proportional solenoid valve
(schematic items N, P, R, T, V)
3.5 to
5.5Ω
Solenoid valve, 3 position 4 way
(schematic item B)
4 t
o 6Ω
Solenoid valve, 3 position 4 way
(schematic items BN, BO, BP, BQ)
7 t
o 9Ω
Solenoid valve, 3 position 4 way
(schematic item AH )
8 to
10Ω
Proportional solenoid valve, 3 position 4 way
(schematic items Y, AI)
8 to
10Ω
Solenoid Valve, 2 position 3 way
(schematic items F, AD)
5.5 to
7.5Ω
Solenoid Valve, 2 position 3 way
(schematic item AE, AF)
8 to
10Ω
Solenoid Valve, 2 position 3 way
(schematic items H, J)
3.5 to
5.5Ω
Solenoid Valve, 2 position 3 way
(schematic items C, D, G, I, K, AX, AY, BU, BT)
7.5 to
9.5Ω
Solenoid valve, 2 position 2 way
(schematic item A)
3.5 to
5.5Ω
Summary of Contents for Genie Z-135/70
Page 14: ......
Page 37: ...October 2018 Service and Repair Manual Specifications Part No 1268557GT Z 135 70 23 T ...
Page 135: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 121 ...
Page 137: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 123 ...
Page 139: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 125 ...
Page 141: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 127 ...
Page 147: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 133 ...
Page 153: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 139 ...
Page 155: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 141 ...
Page 159: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 145 ...
Page 161: ...October 2018 Service and Repair Manual Manifolds Part No 1268557GT Z 135 70 147 ...
Page 233: ...October 2018 Service and Repair Manual 219 Generator Wiring Schematic ...
Page 236: ...Service and Repair Manual October 2018 222 Hydraulic Generator Welder Option ...
Page 242: ...Service and Repair Manual October 2018 228 Hydraulic Schematic from serial number 535 ...
Page 244: ......