Service and Repair Manual
October 2019
Deutz D 2.9 L4 Engine Fault Codes
134
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
Part No. 1280490GT
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
4766
0
1029 Physical range check high for
exhaust gas temperature
downstream (DOC)
4766
1
1032 Physical range check low for
exhaust gas temperature
downstream (DOC)
4768
2
1036 Sensor exhaust gas temperature
upstream (DOC); plausibility
error
4768
3
1044 Sensor error exhaust gas
temperature upstream (DOC);
signal range check high
4768
4
1045 Sensor error exhaust gas
temperature upstream (DOC)
signal range check low
4769
2
1026 Sensor exhaust gas temperature
downstream (DOC); plausibility
error
4769
3
1034 Sensor error exhaust gas
temperature downstream (DOC);
signal range check high
4769
4
1035 Sensor error exhaust gas
temperature downstream (DOC);
signal range check low
523006 3
34
Controller mode switch; short
circuit to battery
523006 4
35
Controller mode switch; short
circuit to ground
523008 1
648 Manipulation control was
triggered
523008 2
649 Timeout error in Manipulation
control
523009 9
825 Pressure Relief Valve (PRV)
reached maximun allowed
opening count
523009 10 833 Pressure relief valve (PRV)
reached maximun allowed open
time
SPN
FMI KWP Description
523212 9
171 Timeout Error of
CAN-Receive-Frame
ComEngPrt; Engine Protection
523216 9
198 Timeout Error of
CAN-Receive-Frame
PrHtEnCmd; pre-heat command,
engine command
523240 9
179 Timeout CAN-message
FunModCtl; Function Mode
Control
523350 4
565 Injector cylinder-bank 1; short
circuit
523352 4
566 Injector cylinder-bank 2; short
circuit
523354 12 567 Injector powerstage output defect
523470 2
826 Pressure Relief Valve (PRV)
forced to open; performed by
pressure increase
523470 2
827 Pressure Relief Valve (PRV)
forced to open; performed by
pressure shock
523470 7
876 Maximum rail pressure in limp
home mode exceeded (PRV)
523470 11 831 The PRV can not be opened at
this operating point with a
pressure shock
523470 11 832 Rail pressure out of tolerance
range
523470 12 828 Open Pressure Relief Valve
(PRV); shut off condition
523470 12 829 Open Pressure Relief Valve
(PRV); warning condition
523470 14 830 Pressure Relief Valve (PRV) is
open
523550 12 980 T50 start switch active for too
long
523601 13 948 Sensor supply voltage monitor 3
error (ECU)
523603 9
126 Timeout Error of
CAN-Receive-Frame AMB;
Ambient Temperature Sensor
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......