October 2019
Service and Repair Manual
Control System Fault Codes
Part No. 1280490GT
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
123
ID Component ID Name
Cause
Effect
Solution
80 Turntable
Controller
(TCON)
13 Not
detected
The DISCON has
not detected the
TCON on the CAN
bus.
Machine limited to
recovery functions
* Verify TCON is receiving power.
Check for 12 V on J5-2 (+) and J5-1
(-).
* Verify TCON is receiving ESTOP
signals. With ground ESTOP pulled
out and keyswitch set to Ground,
verify 12 V is reaching TCON J5-9
and J5-12.
* Verify CAN bus is functional. Pull out
connector J5 from the TCON and with
a voltmeter set to resistance verify
that pins 3 and 4 on the harness
connector measure between 55 and
65 Ohms. Check wiring and boom
cable for open or short circuits if
resistance check fails.
* Replace TCON if necessary.
29 Software
version
mismatch
TCON software is
out of date
Download latest software from
firmware site and update machine.
82 Overload
21 Recovery This is a flag that
indicates that the
platform was
overloaded and
that auxiliary
function enable
was used while
overloaded.
Advisory condition.
Machine is fully
functional.
Power up the machine in service
mode and clear the flag in the service
menu on the ground control display.
83 Disabled
21 By owner The telematics
module has locked
out machine
operation.
Machine will not be
functional, or have
limited functionality,
depending on the
telematics option.
Call machine owner to re-enable
machine functions.
84 Chassis
Angle
13 Not
detected
The tilt sensor S80
has not been
detected on the
CAN bus.
Boom Up, Extend
and Drive functions
will not operate.
* Verify S8O is receiving power.
Disconnect sensor connector and
verify harness connector pins 1 and 2
measure 12 V.
* Verify CAN bus wiring. With a
voltmeter set to resistance, check the
resistance between pins 3 and 4 on
the harness connector (not the
sensor's integrated connector).
Resistance should be between 55 and
65 ohms. Check CAN wiring if
resistance check fails.
* Replace sensor if required.
17 Not
calibrated
Tilt sensor not
calibrated
Machine limited to
recovery functions
Calibrate tilt sensor.
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......