Service and Repair Manual
October 2019
Generators
90
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
Part No. 1280490GT
Gen erators
12- 1 Hydraulic Gener ator
12-1
Hydraulic Generator
How to Adjust the Generator
Frequency
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Note: Perform this procedure with the machine on
a firm, level surface.
Note: This procedure will require a digital
multimeter (DMM) with a frequency counter.
1 Set the multimeter to read frequency and 110
vac and connect the leads to the 110 vac
receptacle.
2 Start the engine and then start the generator.
The engine will go to high idle.
3 Locate the generator manifold on the turntable
tray by the fuel tank and loosen the jam nut on
the needle valve identified in the illustration.
Generator Manifold
1 needle valve
4 Adjust the valve counter-clockwise to increase
the frequency and clockwise to decrease the
frequency, until the correct value is reached
according to the table below.
ANSI
12 kW Generator 61 Hz
+/- 0.5 Hz
ANSI
3 kW Generator
61 Hz
+/- 0.5 Hz
CE / ROW 3 kW Generator
51 Hz
+/- 0.5 Hz
Once the correct frequency is set, tighten the
jam nut.
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...