Service and Repair Manual
October 2019
Deutz D 2.9 L4 Engine Fault Codes
132
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
Part No. 1280490GT
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI KWP
Description
654 3
583
Injector 4 (in firing order); short
circuit
654 4
589
High side to low side short circuit
in the injector 4 (in firing order)
654 5
571
Injector 4 (in firing order);
interruption of electric connection
676 11
543
Cold start aid relay error.
676 11
544
Cold start aid relay open load
677 3
956
Starter relay high side; short
circuit to battery
677 3
960
Starter relay low side; short
circuit to battery
677 4
957
Starter relay high side; short
circuit to ground
677 4
961
Starter relay low side; short
circuit to ground
677 5
958
Starter relay; no load error
677 12
959
Starter relay; powerstage over
temperature
703 3
426
Engine running lamp; short circuit
to battery
703 4
427
Engine running lamp; short circuit
to ground
703 5
424
Engine running lamp; open load
703 12
425
Engine running lamp;
powerstage over temperature
729 5
545
Cold start aid relay open load
729 12
547
Cold start aid relay; over
temperature error
898 9
305
Timeout Error of
CAN-Receive-Frame TSC1TE;
Setpoint
1079 13
946
Sensor supply voltage monitor 1
error (ECU)
1080 13
947
Sensor supply voltage monitor 2
error (ECU)
SPN FMI KWP
Description
1109 2
121
Engine shut off demand ignored
1136 0
1398
Physikal range check high for
ECU temperature
1136 1
1399
Physikal range check low for
ECU temperature
1136 3
1400
Sensor error ECU temperature;
signal range check high
1136 4
1401
Sensor error ECU temperature;
signal range check low
1176 3
849
Sensor error pressure sensor
upstream turbine; signal range
check high
1176 4
850
Sensor error pressure sensor
downstream turbine; signal range
check high
1180 0
1193
Physical range check high for
exhaust gas temperature
upstream turbine
1180 0
1460
Turbocharger Wastegate CAN
feedback; warning threshold
exceeded
1180 0
1462
Exhaust gas temperature
upstream turbine; warning
threshold exceeded
1180 1
1194
Physical range check low for
exhaust gas temperature
upstream turbine
1180 1
1461
Turbocharger Wastegate CAN
feedback; shut off threshold
exceeded
1180 1
1463
Exhaust gas temperature
upstream turbine; shut off
threshold exceeded
1180 3
1067
Sensor error exhaust gas
temperature upstream turbine;
signal range check high
1180 11
1066
Sensor exhaust gas temperature
upstream turbine; plausibility
error
1188 2
1414
Wastegate; status message from
ECU missing
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......