October 2019
Service and Repair Manual
Control System
Part No. 1280490GT
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
25
Screen or Menu
Item
Default
Perkins 404F
Anti-Stall
Threshold
2350 rpm
Drive Minimum
50%
Range
125 rpm
Hysteresis
100 rpm
Screen or Menu
Item
Default
Perkins 404D
Anti-Stall
Threshold
2350 rpm
Drive Minimum
50%
Range
125 rpm
Hysteresis
100 rpm
Screen or Menu
Item
Default
GM 3.0L
Anti-Stall
Threshold
2190 rpm
Drive Minimum
70%
Range
125 rpm
Hysteresis
125 rpm
Screen or Menu
Item
Default
Primary Boom Lift
Speeds
Extend Threshold
212% max, 1% min, 100% = 460mA
Retract Threshold
169% max, 1% min, 100% = 460mA
Up Threshold
186% max, 1% min, 100% = 560mA
Down Threshold
292% max, 1% min, 100% = 400mA
Extend Max
150% max, 66% min, 100% = 1499mA
Retract Max
150% max, 71% min, 100% = 1096mA
Up Max
150% max, 69% min, 100% = 1530mA
Down Max
150% max, 61% min, 100% = 1937mA
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......