Service and Repair Manual
October 2019
Control System
22
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
Part No. 1280490GT
How to Adj ust the Joystick Thr eshol d Setting
How to Adjust the Joystick
Threshold Setting
The threshold setting of a joystick is the minimum
output at which a function proportional valve can
open and allow the function to operate.
The boom function threshold current should be
operating at near zero speed, smoothly with no
vibrations.
Note: Perform this procedure with the boom in the
stowed position.
1 Enter the Service Mode.
2 Press the
SETTINGS
button above the display
screen.
3 Select
SPEEDS
from the display screen.
4 Navigate to the desired function's Threshold
setting.
5 Select the desired setting to change and press
OK
.
6 In the parameter adjustment screen, use the
display buttons to change the parameter. Note
that the factory default speed is considered
100% for threshold values.
7 Scroll and press
OK
. The change is effective
immediately.
8 Switch the machine control to platform control
and start the engine from the platform
controls..
9 Using the joystick, verify that the function
engages smoothly and without sudden
movement or excessive joystick dead spots.
10 Adjust the parameter in the ground display to
achieve a smooth function threshold.
1-5 H ow to Enter ALC 600 Softw are U pdate Mode
1-5
How to Enter ALC600 Software
Update Mode
1 Go to the Genie website
, select your
machine and ALC600 controller type. Enter
the machine serial number and part number
for the software.
2 Download the software to a USB flash drive. If
zipped, extract the files to the USB flash drive.
3 With the machine off, open the GBOX (ground
box) lid and then remove the four Torx head
screws securing the Display Controller
(DISCON) door and remove the door to
expose the USB port.
4 Insert the flash drive into the USB port.
5 Set key switch to ground and pull out the red
ground ESTOP while holding buttons 1 and 4.
6 The Display Controller will go into the
bootloader mode.
7 Browse and select the desired
software. Follow the on-screen guidance to
start the update procedure.
8 When complete, turn off machine.
9 Remove USB flash drive, re-install the Display
Controller door and close the GBOX (ground
box).
10 Power up normally.
11 As the display controller starts, operator shall
verify on the start-up screen that the proper
software and revision are displayed.
12 Perform a function check.
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......