October 2019
Service and Repair Manual
Deutz D 2.9 L4 Engine Fault Codes
Part No. 1280490GT
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
135
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
523605 9
300 Timeout Error of
CAN-Receive-Frame TSC1AE;
Traction Control
523606 9
301 Timeout Error of
CAN-Receive-Frame TSC1AR;
Retarder
523612 12 387 Internal software error ECU;
injection cut off
523612 12 612 Internal ECU monitoring
detection reported error
523612 12 613 Internal ECU monitoring
detection reported error
523612 12 614 Internal ECU monitoring
detection reported error
523612 12 615 Internal ECU monitoring
detection reported error
523612 12 616 Internal ECU monitoring
detection reported error
523612 12 617 Internal ECU monitoring
detection reported error
523612 12 618 Internal ECU monitoring
detection reported error
523612 12 619 Internal ECU monitoring
detection reported error
523612 12 620 Internal ECU monitoring
detection reported error
523612 12 621 Internal ECU monitoring
detection reported error
523612 12 623 Internal ECU monitoring
detection reported error
523612 12 624 Internal ECU monitoring
detection reported error
523612 12 625 Internal ECU monitoring
detection reported error
523612 12 627 Internal ECU monitoring
detection reported error
523612 12 628 Internal ECU monitoring
detection reported error
SPN
FMI KWP Description
523612 12 637 Internal ECU monitoring
detection reported error
523612 12 1170 Internal software error ECU
523612 14 973 Softwarereset CPU SWReset_0
523612 14 974 Softwarereset CPU SWReset_1
523612 14 975 Softwarereset CPU SWReset_2
523613 0
856 Maximum positive deviation of
rail pressure exceeded
(RailMeUn0)
523613 0
857 Maximum positive deviation of
rail pressure in metering unit
exceeded (RailMeUn1)
523613 0
858 Railsystem leakage detected
(RailMeUn10)
523613 0
859 Maximum negative deviation of
rail pressure in metering unit
exceeded (RailMeUn2)
523613 0
860 Negative deviation of rail
pressure second stage
(RailMeUn22)
523613 0
862 Maximum rail pressure exceeded
(RailMeUn4)
523613 1
861 Minimum rail pressure exceeded
(RailMeUn3)
523613 2
864 Setpoint of metering unit in
overrun mode not plausible
523615 3
594 Metering unit (Fuel-System);
short circuit to battery highside
523615 3
596 Metering unit (Fuel-System);
short circuit to battery low side
523615 4
595 Metering unit (Fuel-System);
short circuit to ground high side
523615 4
597 Metering Unit (Fuel-System);
short circuit to ground low side
523615 5
592 Metering unit (Fuel-System);
open load
523615 12 593 Metering unit (Fuel-System);
powerstage over temperature
523619 2
488 Physical range check high for
exhaust gas temperature
upstrem (SCR-CAT)
523698 11 122 Shut off request from supervisory
monitoring function
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......