October 2019
Service and Repair Manual
Specifications
Part No. 1280490GT
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
3
Do not top off with incompatible
hydraulic fluids. Hydraulic fluids
may be incompatible due to the
differences in base additive
chemistry. When incompatible
fluids are mixed, insoluble
materials may form and deposit
in the hydraulic system,
plugging hydraulic lines, filters,
control valves and may result in
component damage.
Note: Do not operate the machine when the
ambient air temperature is consistently above
120°F / 49°C.
Hydraulic Fluid Temperature
Range
Ambient air temperature
1 Chevron hydraulic oil 5606A
2 Petro-Canada Environ MV 46
3 UCON Hydrolube HP-5046D
4 Chevron Rando HD premium oil MV
Chevron Rando HD Premium Oil
MV Fluid Properties
ISO Grade
32
Viscosity index
200
Kinematic Viscosity
cSt @ 200°F / 100°C
cSt @ 104°F / 40°C
7.5
33.5
Brookfield Viscosity
cP @ -4°F / -20°C
cP @ -22°F / -30°C
1040
3310
Flash point
375°F / 190°C
Pour point
-58°F / -50°C
Maximum continuous operating
temperature
171°F / 77°C
Note: A hydraulic oil heating system is
recommended when the ambient temperature is
consistently below 0°F / -18°C.
Note: Do not operate the machine when the
ambient temperature is below -20°F / -29°C with
Rando HD Premium MV.
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......