Part No. 57.4400.9203 GTH-4016SR • GTH-4018SR
63
March 2010
REV A
Section 4 • Repair Procedures
Sensors
8-1 How to Remove the Boom
Lenght and Angle Sensor
1. Disconnect the connector
2. Remove the retainer on the cable keeping a lot
of attention.
3. Remove the screws.
4. Remove the boom lenght and angle sensor.
NOTICE
After reinstalling the sensors,
follow the
“How to Set the
Overload Warning System”
paragraph.
8-2 How to Test the Boom Lenght
and Angle Sensor
1. See paragraph “Overload Warning System
Fault Codes” from point 5 to point 10.