TIME DELAY FOR OPERATION MODE
This parameter defines the time delay between the end of the programming (valid
thresholds are set) sequence and the device going into operation mode. Extending the
time delay parameter can be useful in cases when more time is required for preparing the
operation environment.
Slave ID
: 1 to 247
Address location
: 4
Value
: 2 to 300 (in seconds, default 2)
NO/NC ACTIVE REGION (applicable to mode 3, 4 and 5)
This boolean parameter defines the trigger zone(s) for the NO/NC output.
NO/NC ACTIVE REGION = 0: when trigger is detected between the Threshold_1 and
Threshold_2, the NO/NC output is activated.
NO/NC ACTIVE REGION = 1: when trigger is detected below the Threshold_1 or between
the Threshold_2 and wall, the NO/NC output is activated.
Slave ID
: 1 to 247
Address location
: 10
Value
: 0 or 1 (default 0)
Note:
Not applicable to operating modes 1 and 2, as they only implement a single Background
Threshold). In these modes, the NO/NC output will be triggered on every detection within
the selected trigger zone.
OPERATING MODE SELECT
Selects the sensors operating mode.
Slave ID
: 1 to 247
Address location
: 14
Value
: 1 to 6
(mode 1=1, mode 2=2, mode 3=3, mode 4=4, mode 5 =5, mode 6=6)