LED signalization sequence
Table 8 - Mode 2 LED signalization sequence
Phase
LED designators Action
Function
Setup
Th1; Th2
Both LEDs will go from ON
(GREEN) to OFF status for 2
s (default)
Indicates a properly stored
background distance
Th1; Th2
Both LEDs will stay
continuously ON (GREEN)
Indicates that setup is finalized
and sensor is in operation
mode
Operation
Th1; Th2
Both LEDs will blink GREEN
once
Indicates that an object has just
left the Field of View
4.5.
Operating mode 3
Description
In mode 3, a switching window is taught in between the sensor and the background
threshold. The sensor is activated as soon as an object or a person enters the selected
trigger zone(s). This mode is used for monitoring a frontal approach or level fulfilment, for
instance.
Please note that mode 3 is not recommended for monitoring lateral movement or
detecting small objects. Obstacles that partially enter the sensors Field of View
may be detected at an incorrect distance, caused by an averaging effect (refer to
).
Copyright © Terabee 2019