Table 6 - Operating modes
Operating mode
Setup
Operation
Switching output (NO/NC)
Distance data
1
1 threshold
Output is triggered as soon as an
object BREAKS the light beam in the
trigger zone.
Output remains triggered as long as
the light beam in the trigger zone is
broken.
Available via RS485
(Modbus)
2
1 threshold
Output is triggered as soon as an
object LEAVES the light beam in the
trigger zone. *
Available via RS485
(Modbus)
3
3 thresholds Output is triggered as soon as an
object ENTERS the trigger zone.
Output remains triggered as long as
the light beam in the trigger zone is
broken.
Available via RS485
(Modbus)
4
3 thresholds
Output is triggered as soon as an
object LEAVES the trigger zone of
the light beam. *
Available via RS485
(Modbus)
5
3 thresholds Output is triggered as soon as an
object LEAVES the trigger zone of
the light beam. *
Available via RS485
(Modbus)
6
No setup
No switching output
Available via RS485
(Modbus)
*
The sensor is not triggered while the light beam in the trigger zone is broken (applicable to modes 2, 4 and 5)
Copyright © Terabee 2019
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
15/47