![TeraBee ND-TOF-1 User Manual Download Page 24](http://html1.mh-extra.com/html/terabee/nd-tof-1/nd-tof-1_user-manual_1088195024.webp)
Figure 15. Mode 3 operation for NO/NC Active region = 1
⇒
Only white patched areas (Th2<
distance OR distance <Th1) are triggering the switching output
The following table summarizes the detection model for mode 3.
Table 9 - NO/NC active regions for mode 3
Location of detection
LED indication / color Switching output
status (NO/NC
active region = 0)
Switching output
status (NO/NC
active region = 1)
Between the sensors
minimum distance (50 cm)
and the Threshold 1
Th1 stays continuously
ON / RED
OFF
ON
Between Threshold 1 and
Threshold 2
Th1 and Th2
continuously blinking /
GREEN
ON
OFF
Between the Threshold 2
and the Background
threshold
Th2 stays continuously
ON / RED
OFF
ON
Greater than or at
background threshold
distance
Th1 and Th2 stay
continuously ON /
GREEN
OFF
OFF
Copyright © Terabee 2019
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
24/47