The following table summarizes the detection outcomes for mode 5:
Table 13 - NO/NC active regions in mode 5
Location of the detection
LED indication /
color
Switching
output status
(NO/NC active
region = 0)
Switching output
status (NO/NC
active region = 1)
Between the sensors minimum
distance (50 cm) and the Threshold 1
Th1 blinks RED
once
OFF
ON
Between Threshold 1 and Threshold
2
Th1 and Th2
blink GREEN
once
ON
OFF
Between the Threshold 2 and the
Background threshold
Th2 blinks RED
once
OFF
ON
Detection greater than or at
background threshold distance
Th1 and Th2 stay
continuously ON
/ GREEN
OFF
OFF
Rolling buffer (5 measurements)
After an object has entirely left the light beam of the trigger zone, the distance that was
recorded during detection, is stored in a register as the measured distance to object. The
sensor has the capacity to store 5 measurements at the same time. Every new
measurement will erase the oldest (5
th
) value from the device. This functionality allows to
obtain accurate distance-to-target feedback as an added layer of intelligence, in addition to
the NO/NC switching output. Please refer to
LED signalization sequence
Table 14 - Mode 5 LED signalization sequence
Phase
LED
designators
Action
Function
Setup
Th1; Th2
LEDs blinks
continuously
GREEN
Indicates a properly stored background
distance and signals that the device is
ready for detection area setup.
Th1; Th2
LEDs stay
continuously ON
(GREEN)
Indicates that setup is finalized and sensor
is in operation mode.