When choosing a place for installation, please consider the following
recommendations:
●
During setup and operation, please make sure that the sensor is not
pointing at a distance longer than the maximum offered range (12.5
meters). Please ensure that a physical object/obstruction (e.g wall) is
covering the sensors entire Field of View, no further than the maximum
range (12.5 meters) of the sensor
●
It is recommended to install the sensor min. 70 cm from the
measuring/monitoring objects in your application. Please note that
mounting the sensor with a distance smaller than 70 cm from the
measured object, can affect the sensor absolute accuracy
●
Mounting close to sources of heat or strong electromagnetic fields can
decrease the sensing performance
●
Do not mount anything directly in front of the sensor
●
Within the first meter from the sensor avoid objects with high surface
reflectivity in a cone of approximately ± 45° around the central optical axis
of the sensor
●
It is better to avoid having other sources of continuous wave or modulated
IR light close to the sensor