Setup
Figure 13. Mode 3 setup phases.
Step 1 - Set background threshold
●
Make sure that an object is fully covering the sensors Field of View at the preferred
background distance, then hold the PROG button for 1 second.
●
The background threshold is now stored and the LED indicator, Th1, will start
blinking GREEN to signal that the sensor is ready for Threshold 1 (Th1) setup.
Step 2 - Set Threshold 1 (Th1)
●
Make sure that an object is fully covering the sensors Field of View at the preferred
Threshold 1 (Th1) distance, then press the SET button.
●
The LED indicator, Th1, will now stay continuously ON (GREEN) to verify a properly
stored threshold.
●
The LED indicator, Th2, will start blinking GREEN to signal that the sensor is ready
for Threshold 2 (Th2) setup.
Step 3 - Set Threshold 2 (Th2)
●
Make sure that an object is fully covering the sensors Field of View at the preferred
distance, greater than threshold 1, then press the SET button.
●
The LED indicator, Th2, will continuously stay ON (GREEN) to verify a properly stored
threshold.
●
Once both thresholds are registered, the sensor will go into “Time delay for
Operation mode” for 2 seconds (default), before initializing operation mode. LED
indicators, Th1 and Th2, will turn OFF during the “Time delay for operation mode”.
See
for more information on configurable parameters.
Copyright © Terabee 2019
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
22/47