The following table summarizes possible detection outcomes for mode 4.
Table 11 - NO/NC active region in mode 4
Location of detection
LED indication /
color
Switching
output status
(NO/NC active
region = 0)
Switching
output status
(NO/NC active
region = 1)
Between the sensors minimum
distance (50 cm) and the
Threshold 1
Th1 blinks RED once OFF
ON
Between Threshold 1 and
Threshold 2
Th1 and Th2 blink
GREEN once
ON
OFF
Between the Threshold 2 and the
Background threshold
Th2 blinks RED once OFF
ON
Detection greater than or at
background threshold distance
Th1 and Th2 stay
continuously ON /
GREEN
OFF
OFF
Rolling buffer (5 measurements)
After an object has entirely left the light beam of the trigger zone, the distance that was
recorded during detection, is stored in a register as the measured distance to object. The
sensor has the capacity to store 5 measurements at the same time. Every new
measurement will erase the oldest (5
th
) value from the device. This functionality allows to
obtain accurate distance-to-target feedback as an added layer of intelligence, in addition to
the NO/NC switching output. Please refer to