The antenna can be mounted either vertically or horizontally polarized. If you are using a Marquee P-MP
with an attached antenna, the label located on the back of the unit shows an arrow indicating the
antenna’s polarization (see Figures 2.7a and b). Please note that both ends of the link must use the
same polarization. Be aware that most omni antennas are vertically polarized and if the Marquee P-MP
EX is aimed at one, it must be installed vertically polarized, i.e., with the polarization arrow up and down.
If you are using a Marquee P-MP with an external antenna, there is no arrow on the label located on the
back of the unit and an additional N-type female jack is present to connect a short coax cable to the
antenna (see Figure 2.1b). All previous considerations regarding polarization are applicable to the
external antenna.
Figure 2.7 – Marquee P-MP EX With Attached Antenna Orientation
(a) For Vertical Polarization
(b) For Horizontal Polarization
Polarization
Arrow
Polarization
Arrow
WARNING
If you are using a Marquee P-MP with an external antenna, the unit must
be operated with a proper antenna, microwave load or terminator
plugged into the N-type female jack on the back of the unit. Operating
the Marquee P-MP with nothing connected to the jack may result in
damage to the TX section of the unit which will not be covered by the
factory warranty and will be a billable repair.
1. Fit the adaptor bracket (A) to the four studs protruding from the back of the Marquee P-MP EX unit, by
aligning the four inner holes with the mounting studs on the back of the unit and securing to the unit
using four nuts, lock washers, and flat washers, as shown in Figure 2.8. Tighten hardware (four
places).
IMPORTANT:
Note the position of the serrated edge of bracket (A).
Attach the pole mounting bracket (B) to adaptor bracket (A) by using one M8x
.
40 bolt and flat washer
.
s,
2
on one side, and nut, lock washer and flat washer on the other, as shown in Fig 2.8. Tighten hardware
(one place).
IMPORTANT:
Ensure that the serrated edges on both brackets are facing each other.
Fasten the unit to the pole using pole clamp (C) and two M8x70 bolts, lock washers, and flat washer
3
as shown in Fig 2.9. Tighten hardware (two places). The pole mounting bracket (B) will accept pole
diameters between 1.75” to 3” OD. You may attach the Marquee P-MP unit to smaller diameter poles,
between 1” to 1.75” OD, by flipping over the pole clamp (C) so the convex part faces the pole and
using two M8x40 bolts. The Marquee P-MP unit can also be mounted to larger pole diameters by
Version 1.3(a)