2.6
Demand Page
In this page, the total current, active power, reactive power
and apparent power demand values are displayed with the
date and Times.
On this page, the "Measurements 1" page is displayed
when the "Measurements" button is pressed. When you
press the "BACK" and "NEXT" buttons, you can see other
demand values.
Current Demand (15min.)
L1
L2
L3
Total
Current (A)
Date
Time
0.000
0.000
0.000
0.000
00/00/0000
00/00/0000
00/00/0000
00/00/0000
00:00
00:00
00:00
00:00
MEASUREMENTS
NEXT
BACK
3.1
Current Transformer
:
The current transformer test / current transformer value
change is made.
3.2
Harmonic Voltage
:
Harmonic Voltage settings are made.
3.3
Harmonic Current
:
Harmonic Current settings are made.
3.4
Device Settings
:
Go to Device settings menu.
3.5
Step
:
G
o to the menu of Step settings.
3.6
Generator
:
Generator settings are made.
3.7
Voltage Min / Max
:
Voltage settings are made.
3.8 Alarm:
Inductive and Capacitive Alarm settings are made.
3.9
Compensation
:
Inductive and Capacitive target settings are made.
3.10
Temperature
:
Temperature Alarm settings are made.
3.11 ModBus:
Modbus
(Communication) settings are made.
Main Page:
Go to
Main Page
.
SETTINGS PAGE
Current Trans.
Device Settings
Step Settings
Temperature
Main Page
ModBus
Generator
Alarm
Alarm
PF Correction
1
+Q
-Q
Voltage Min/Max
V
THDV Set
V
THDI Set
A
3.
Settings Screen
2.7
Min / Max / Average Page
In this page, the minimum (min), maximum (max) and
average (avg) values of current and voltage values are
displayed. (Values are taken with an average of 5 min.)
On this page, the "Measurements 1" page is displayed
when the "Measurements" button is pressed. When you
press the "BACK" and "NEXT" buttons, it is toggle between
the others.
Current Min-Max-Avg (A) (5min.)
L1
L2
L3
Min
Max
Avg
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
MEASUREMENTS
NEXT
BACK
9
When the Settings button is pressed, the
Settings page appears on the screen on
dynamic area.
From this page, you can switch to Current
Transformer, Harmonic Voltage, Harmonic
Current, Device Settings, Step, Generator,
Voltage Min / Max, Alarm, Compensation,
Temperature, Modbus settings and Main Page.
Settings
E
Measurements
E
Measurements Page 2
E
Measurements
E
Measurements Page 2
E