![Tense RGT-MT18 User Manual Download Page 12](http://html1.mh-extra.com/html/tense/rgt-mt18/rgt-mt18_user-manual_1087678012.webp)
2.3
Cosine Page
In this page, the cosine values of each phase are displayed
in figures and graphics.
On this page, the "Measurements 1" page is displayed
when the "Measurements" button is pressed, and the
"Settings" page is displayed when the "Settings" button is
pressed.
MEASUREMENTS
SETTINGS
Cosinus ( COS )
L1
L2
L3
-0.999
-0.999
-0.999
2.4
Harmonic Voltage Page
In this page, up to the 61st harmonic of each phase voltage
is displayed.
On this page, the "Measurements 1" page is displayed
when the "Measurements" button is pressed. When you
press the "BACK" and "NEXT" buttons, you can see
harmonics belong to the other phases.
In this page, it is displayed up to the 61st harmonic of each
phase current.
On this page, the "Measurements 1" page is displayed
when the "Measurements" button is pressed. When you
press the "BACK" and "NEXT" buttons, you can see
harmonics belong to the other phases.
MEASUREMENTS
L1 - Voltage Harmonics
3.
5.
7.
9.
11.
13.
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
15.
17.
19.
21.
23.
25.
27.
29.
31.
33.
35.
37.
39.
41.
43.
45.
47.
49.
51.
53.
55.
57.
59.
61.
NEXT
BACK
In this page, the values of capacitor (sign (-) or shunt
reactor value (each phase separately), connection type and
number of steps usage are displayed.
It is 18+1 step in total. The 19th step is TCR.
Three monophasi (one for each phase) shunt reactor are
connected to this step. Shunt reactors are connected to
driver. Shunt reactors are triggered via the SVC CON
connection.
On this page, the "Measurements 1" page is displayed when the "Measurements" button
is pressed. When you press the "BACK" and "NEXT" buttons, you can pass from one step to
another step.
Step Values
1.
2.
3.
4.
5.
L1
L2
L3
Connection Counter
-0.33 -0.33
0.00
-0,25
0.00
0.00
-0.33
0.00
0.00
-0,25
0.00
L1-2-3
L1
L2
L3
Cancel
10
30
45
1
0
-0,25
0.00
0.00
0.00
MEASUREMENTS
NEXT
BACK
MEASUREMENTS
L1 - Current Harmonics
3.
5.
7.
9.
11.
13.
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
15.
17.
19.
21.
23.
25.
27.
29.
31.
33.
35.
37.
39.
41.
43.
45.
47.
49.
51.
53.
55.
57.
59.
61.
NEXT
BACK
2.5
Harmonic Current Page
2.2
Step Values Page
8
1.00
0.00
Cosine
-1.00
Measurements
E
Measurements Page 2
E
Measurements
E
Measurements Page 2
E
Measurements
E
Measurements Page 2
E
Measurements
E
Measurements Page 2
E
Summary of Contents for RGT-MT18
Page 1: ...RGT MT18 USER GUIDE www tense com tr...
Page 35: ...User Notes 31...