![Tennant 6100E Service Manual Download Page 218](http://html1.mh-extra.com/html/tennant/6100e/6100e_service-manual_1086816218.webp)
ELECTRICAL
4--76
6100E 330255 (9--00)
CONTINUED FROM PREVIOUS PAGE
DISCONNECT 35/YEL AND 36/ORA AT THE
MOTOR CONTROLLER. CHECK THE VOLTAGE
FROM M1 TO M2 AT THE MOTOR CONTROLLER
WITH THE THROTTLE ACTIVATED IN THE FULL
FORWARD POSITION.
LESS THAN 25 VDC
GREATER THAN 25 VDC
REPLACE THE MOTOR CONTROLLER
RECONNECT WIRES 35/YEL AND 36/ORA.
CHECK THE VOLTAGE ACROSS WIRES
35/YEL AND 36/ORA AT THE DISCON-
NECTED PROPEL MOTOR CONNECTOR
WITH THE THROTTLE IN THE FULL FOR-
WARD POSITION.
0 VDC
WIRES 35/YEL, 36/ORA, OR THE
MOTOR CONNECTOR TERMINALS
ARE OPEN.
GREATER THAN 25 VDC
THE PROPEL MOTOR OR ASSOCIATED WIRES
AND CONNECTOR ARE OPEN. REPLACE THE
MOTOR. NOTE: THE RESISTANCE OF A TYPICAL
PROPEL MOTOR IS 1.6 OHMS.
Summary of Contents for 6100E
Page 1: ...330255 Rev 02 6 01 Service Manual 6100E ...
Page 4: ...GENERAL INFORMATION 1 2 6100E 330255 6 01 ...
Page 18: ...CHASSIS 2 2 6100E 330255 9 00 ...
Page 27: ...CHASSIS 2 11 6100E 330255 9 00 7 Remove the hub assembly from the tire assembly ...
Page 82: ...CHASSIS 2 66 6100E 330255 9 00 ...
Page 144: ...ELECTRICAL 4 2 6100E 330255 9 00 ...
Page 210: ...ELECTRICAL 4 68 6100E 330255 6 01 ELECTRICAL SCHEMATIC 1 2 3 ...
Page 211: ...ELECTRICAL 4 69 6100E 330255 6 01 ELECTRICAL SCHEMATIC 1 2 3 ...
Page 212: ...ELECTRICAL 4 70 6100E 330255 6 01 WIRE HARNESS ...
Page 213: ...ELECTRICAL 4 71 6100E 330255 6 01 WIRE HARNESS ...
Page 214: ...ELECTRICAL 4 72 6100E 330255 6 01 WIRE HARNESS ...