TEN Automotive Equipment Limited
7
Version 3.4
Sept 2014
5.
1.
Connect the low pressure male
adaptor to the refrigerant source
tank.
2.
Connect the low pressure “quick
coupler” to the male adaptor.
3.
Open source tank valve and Blue
“quick coupler” valve.
4.
Press the Recover Key
RECOVER 10.00 kg
Note: 10.00kg is the amount of
refrigerant that the Work Tank
can contain.
If male adaptor is not available
use a suitable alternative
coupling to connect low pressure
hose to source tank.
6
Press the START key to begin the
refrigerant filling process.
Please ensure that Source tank and
blue quick coupler valves are open.
RECOVER 00.00 kg
7
When adding refrigerant to Work
Tank the displayed amount will
increase.
Note: Turn source tank upside down
to increase flow, if required.
RECOVER xx.xx kg
8
Suggested weight of refrigerant
adding to Work Tank for the first
time is 3 to 4 kg.
IMPORTANT
: When the displayed
weight is approximately 3 to 4 kg,
close source tank valve and blue
quick coupler valve.
DO NOT PRESS STOP BUTTON !!
When pressure decreases to 0 PSI,
system will automatically complete
recovery process.
RECOVER xx.xx kg
IMPORTANT
: When filling the
Work Tank
DO NOT LEAVE
THE SYSTEM UNATTENDED.
ALWAYS TURN OFF SOURCE
TANK VALVE FIRST !!
9
The screen will display the weight of
the refrigerant added to Work Tank
and then enter the drain A/C system
oil process.
Wait for 10 seconds, system will
automatically drain the A/C system
oil separated from refrigerant.
RECOVER xx.xx kg
DRAIN OIL