TEN Automotive Equipment Limited
16
Version 3.4
Sept 2014
IMPORTANT:
If the system displays TANK EMPTY when you press
the CHARGE key then there is insufficient refrigerant in the Work Tank to charge the vehicle
A/C system. Press the STOP key to exit the recharging process and add refrigerant to the
Work Tank. (Refer to section
8.5
for details).
Back to Index
8.4 Hose recovery and system self-cleaning
STEP
OPERATION
OPERATING
INSTRUCTION
SCREEN DISPLAY
1
Turn the power switch on.
From System Standby:
1.
Make sure that high and low
quick couplers are not connected
to vehicle.
2.
Ensure that the high and low
quick coupler valves are closed.
WEIGHT xx.xx kg
2
Press the RECOVER key to enter
into recovery procedure.
xx.xx kg is reading of “headroom”
left in Work Tank
.
RECOVER xx.xx kg
3
Press the START to begin hose
recovery or self-cleaning.
Check pressure gauge
When the pressure is lower than
0kpa, system will automatically
complete the process.
RECOVER xx.xx kg
4
The screen will display the weight of
the refrigerant recovered from hoses
and proceed to discharge old A/C
system oil and contaminants.
RECOVER xx.xx kg
DRAIN OIL
5
When Drain Oil is complete press
STOP key down for 3 seconds to go
back to System Standby. Hose
recovery and system self-cleaning is
complete.
WEIGHT xx.xx kg
TANK EMPTY