TEN Automotive Equipment Limited
23
Version 3.4
Sept 2014
25
Important Note:
Please allow 90 seconds for the N2
exhausting process to complete.
During this time the system is not
operable. This is to ensure complete
exhausting of N2 from the system.
EXHAUSTING
26
Note: If you press STOP during N2
exhausting process, the System will
exit the automatic program and not
carry out the other programmed
functions (i.e. vacuum, oil injection
and charging processes).
EXHAUSTING
27
System will automatically enter into
Vacuum procedure according to
program setting. Vacuum time is
preset by the operator.
VACUUM xx.xx
28
System will enter into vacuum hold
procedure according to program
setting automatically, vacuum hold
time is set time. Note: This is a
Pressure Gauge Check only.
VAC HOLD 3:00
29
System will automatically enter into
Oil Injection procedure.
INJECT OIL
30
System will inject oil approximately
to the pre-set amount.
NOTE: If the
initial amount was set to 0ML then
enter the amount of oil to inject at
this point.
INJECT xx ML
31
System will automatically enter into
refrigerant charging procedure. The
amount of refrigerant is the preset by
the operator.
CHARGE xx.xx kg
32
When charging refrigerant reaches
preset weight, the System will
display CHARGE COMPLETE.
CHARGE xx.xx kg
CHARGE COMPLETE