TEN Automotive Equipment Limited
11
Version 3.4
Sept 2014
8: OPERATION
8.1 Recover refrigerant and draining A/C system oil
STEP
OPERATION
OPERATING
INSTRUCTION
SCREEN DISPLAY
1
Turn mains power switch on.
Now the system enters into system
self-checking state and displays
software version.
VERSION x.xx
2
After 3 seconds, the system will
display the weight of refrigerant in
the Work Tank.
Connect red and/or blue quick
couplers to high and low pressure
hoses of the vehicle A/C system
and open coupler valves.
WEIGHT xx.xx kg
3
IMPORTANT: Check gauges for
vehicle A/C operating pressure.
If zero pressure is displayed then
check the vehicle A/C system for
leaks first.
Note: The VACUUM HOLD test
is a visual check using the Gauges
to look for vacuum decay. It is
recommended that the Nitrogen
Pressure Test is used for leak
detection.
WEIGHT xx.xx kg
4
Press RECOVER key to enter into
recovery procedure.
xx.xx kg is reading of headroom
left in Work Tank.
RECOVER xx.xx kg
5
Press the START key to begin
recovery. When the pressure in the
vehicle A/C system is lower than 0
kpa, the system will automatically
complete recovery process.
RECOVER xx.xx kg