TEN Automotive Equipment Limited
22
Version 3.4
Sept 2014
21
If N2 has been selected then after the
recovery and oil draining, the system
will automatically enter into N2
charging process. When pressure of
N2 charged into air conditioner of
vehicle reaches the set value (10bar),
N2 charging process will be
completed automatically, and system
will automatically enter into high
pressure leakage detecting process.
N2 CHARGING
22
After N2 charging process is
automatically completed,
1.
Within set time, System will
check the leakage for vehicle
A/C system. Press STOP to
pause the countdown and enter
into manual leakage checking
procedure.
2.
Press START to continue
checking leakage automatically.
N2 LK TEST 15:00
23
Note:
1.
Press STOP to pause the
countdown to manually check
for leaks.
2. Press START to continue
leakage checking countdown.
N2 LK TEST 15:00
24
Important Note: If 400mbar pressure
decay is detected when the preset
time is reached the System will
display LEAKAGE, and an audible
warning will send out
simultaneously.
Press START to cancel audible
warning.
Press STOP to discharge and exit
Nitrogen pressure test program.
LEAKAGE