TEN Automotive Equipment Limited
19
Version 3.4
Sept 2014
3
Press START, to program the
function sequence selection.
Note: The Fully Automatic sequence
of operating functions may now be
programmed using the number keys
0 through to 7.
Please refer to function chart below
keypad on unit front panel.
SELECT FUNCTION
4
Press number key 1. Recovery
function will be chosen.
Press number key 1 again; Recovery
function will be cancelled.
R
5
Press number key 2. Nitrogen
pressure test will be selected.
Press number key 2 again; nitrogen
pressure test will be cancelled.
R-N2
R
6
Press number key 3. Vacuum
function will be chosen.
Press number key 3 again; vacuum
function will be cancelled.
R-N2-V
R-N2
7
Press number key 4, vacuum hold
time will be chosen.
Press number key 4 again; vacuum
hold
will be cancelled.
NOTE: This is a Pressure Gauge
Check only.
R-N2-V-
VH
R-N2-V
8
Press number key 5. Oil Injection
will be selected.
Press number key 5 again; Oil
Injection will be cancelled.
R-N2-V-
VH
-I
R-N2-V-
VH
9
Press number key 6. High and low
pressure port refrigerant charging
will be selected.
Press number key 6 again; high and
low pressure refrigerant charging will
be cancelled.
R-N2-V-
VH
-I-C
R-N2-V-
VH
-I