TEN Automotive Equipment Limited
20
Version 3.4
Sept 2014
10
Press number key 7. Low pressure
port only refrigerant charging will be
selected.
Press number key 7 again; low
pressure port charging will be
cancelled.
R-N2-V-
VH
-I-LC
R-N2-V-VH -I-
11
If you want to exit all the above
chosen functions, press STOP to go
back to Select Function mode, and
press START to return to system
standby mode.
To confirm the selected functions,
press START.
WEIGHT xx.xx kg
SELECT FUNCTION
12
To enter into vacuum time set, and
press number keys to set vacuum
time value. Then press START.
VACUUM 30:00
13
To enter the amount of oil to recharge
set charging weight by number keys.
NOTE: Set the amount to 00ML if
you wish to enter the amount of oil
equal to the amount of drained oil
prior to INJECT OIL
OIL 10ML
14
To enter the amount of refrigerant to
recharge set charging weight by
number keys.
CHARGE 00.90kg
15
IMPORTANT:
The Work Tank must contain at least
1.2kg more than the charge weight
entered. If not the error message
TANK EMPTY? Will be displayed.
Press STOP to exit program and add
refrigerant to Work Tank (Refer to
4.5).
TANK EMPTY?