Phone  number

:  the  number  to  which  the  system  sends  SMS  and/or  initiates  a  call  upon 

activating  the  given  input.  It  is  recommended  to  enter  the  phone  number  in  international 
format (like: +3630…). 

Notification type

: the way of notifying the given phone number when the input is activated. 

This  option  is 

not available if “

Online  mode

” is enabled at the internet access settings. In 

this case the system can only send SMS, all call options are unavailable! 

SMS

:  if  you  choose  this  option,  the  system  will  send  SMS  only  to  the  given  phone 

number, using the entered message. 

Call

:  if  you  choose  this  option,  the  system  will  make  a  call  only  to  the  given  phone 

number. The system does not play any sound or voice message in the call. This function 
only serves to ring a phone number upon activating an input, thus the notification is free 
of charge if the called party does not accept or rejects the call. 

SMS + Call

: if you choose this option, the system will send SMS and will initiate a call 

too to the given phone number. 

Call duration

: for notification by call it can be configured how long the called phone device 

should  ring.  When  the  configured  period  of  time  expires,  the  system  terminates  the  call 
automatically,  or  the  called  party  may  also  reject  the  call  earlier.  The  notification  is free of 
charge if the called party does not accept or rejects the call (please also check this with your 
GSM service provider because at some providers there might be differences in this service). 
This option is not available if “

Online mode

” is enabled at the internet access settings. 

E-mail  address

:  the  address  to  which  the  system  sends  e-mail  upon  activating  the  given 

input. You can enter multiple e-mail addresses separated by comma. If you wish to use the 
emailing  services  of  the  system,  it  is  necessary  to  configure  the  internet  access  and  the 
outgoing e-mail account settings. 

Message

:  the  message  to  be  sent  by  SMS  and/or  e-mail  upon  activating  the  given  input. 

Attention! The following characters should not be used: 

~ ^ < > = ’ ” , | $ & 

Position limit switch OUT1

: enabling on input IN3 the gate position limit switch installed on 

the gate controlled by output OUT1. If the gate position limit switch is connected, the module 
monitors  if  the  gate  opens  within  the  time  interval  configured  in 

the  “

Opening  timeout

” 

section, and if it closes 

within the time interval configured in the “

Closing timeout

” section. 

If  the  gate  fails  to  open  or  close  within  the  configured  intervals,  the  module  sends 
notifications  by  Push  notification  and/or  SMS,  according  to  the  settings.  The  messages  of 
the  notifications  can be  changed  in  the 

Customization

” menu. The system considers the 

idle state of the position limit switch as the closed state of the gate. In case of NO (normally 
open)  wiring,  the  open  state,  while  for  NC  (normally  closed)  wiring  the  closed  state  of  the 
position limit switch is considered as idle state. 

None

: there is no position limit switch connected to input IN3 

Connected

: the position limit switch is connected to input IN3 

Position limit switch OUT2

: enabling on input IN4 the gate position limit switch installed on 

the gate controlled by output OUT2. This option is only available for control modes 1 and 2, 
for  connecting  the  second  gate’s  position  limit  switch.  If  the  gate  position  limit  switch  is 
connected, the module monitors if the gate  opens within the time interval configured in the 

Opening  timeout

”  section,  and  if  it  closes  within  the  time  interval  configured  in  the 

Closing timeout

” section. If the gate fails to open or close within the configured intervals, 

the module  sends  notifications  by  Push  notification  and/or  SMS,  according  to  the  settings. 
The messages of the notifications can be changed in the “

Customization

” menu. In case of 

NO (normally open) wiring, the open state, while for NC (normally closed) wiring the closed 
state of the position limit switch is considered as idle state. 

None

: there is no position limit switch connected to input IN4 

Connected

: the position limit switch is connected to input IN4 

Summary of Contents for GSM Gate Control Pro 1000

Page 1: ...caller identification 5 different control modes 4 NO NC inputs 2 NO relay outputs 50 configurable access templates Configurable holidays Automatic timed controls 20 and 1000 user variant Reports the s...

Page 2: ...nfiguring by computer via USB 11 4 3 Configuring by computer over the Internet 11 4 3 1 Adding a client identifier for the programming software 12 4 3 2 Managing SIM identifiers 13 4 3 3 Steps of remo...

Page 3: ...ent permissions and access periods as well as custom access rules can be assigned The access periods can be configured by access templates which can be assigned to users The system will accept control...

Page 4: ...while the position limit switch of gate B should be connected to input IN4 In case of control modes 3 4 and 5 the gate s position limit switch should be connected to input IN3 If the position limit s...

Page 5: ...g on the product type if the supply voltage drops below 8 4 8 2V the module turns off automatically and it turns back on when the supply voltage is at least 11 2 11 4V The minimum supply voltage level...

Page 6: ...tput OUT1 should be connected to input IN3 If two gates are controlled the position limit switch of the gate controlled by output OUT2 should be connected to input IN4 For control modes 3 4 and 5 the...

Page 7: ...d 5 Wiring example for control mode 3 The example shows wiring of inputs IN1 and IN2 when configured to normally open and when inputs IN3 and IN4 are configured to normally closed The example shows wi...

Page 8: ...to open the socket 3 slide the SIM card into the opened part with the contacts facing down as shown in the figure Close back the opened part together with the SIM card Press down carefully the metalli...

Page 9: ...to the module Check the wires to be connected as instructed in the wiring diagram You can power up the device 9 30 VAC DC Make sure that the power source is sufficient for the operation of the Gate C...

Page 10: ...of the installation wizard to complete the installation The latest version of the programming software can be downloaded from the manufacturer s website https tell hu en products gsm automation gsm g...

Page 11: ...d the event log can be downloaded and status information is also available 4 3 Configuring by computer over the Internet For connecting via the Internet the SIM card installed into the Gate Control Pr...

Page 12: ...entifier window then select the Password for remote programming option in the Client identifier section and enter the new password here The software will ask for this password and the user name of the...

Page 13: ...dentifiers button In the SIM identifier editor window you can add new SIM identifiers delete existing ones and change the name and identifier number of existing ones Adding a new SIM identifier To add...

Page 14: ...e Internet green After connecting successfully the settings can be read and changed the event log can be downloaded and the status information can be viewed just like when connected via USB Of course...

Page 15: ...uptime since the last GSM network connection IP uptime the uptime since the last internet connection GSM operator the name of the GSM operator used actually GSM signal actual GSM signal level Lowest...

Page 16: ...ent log to file in CSV format Reading the event log from the module When reading the event log you can specify by filtering options the period and event type you wish to download It is also possible t...

Page 17: ...on Create full system backup You can create a full system backup after clicking on this button The full system backup includes all the settings as well as users database client identifiers templates a...

Page 18: ...ation for backup GSM calls and for SMS sending during the smart device registration process PIN code if you wish to use PIN code management enter here the PIN code of the SIM card installed into the m...

Page 19: ...rol call by calling back the given number Callback option can be enabled separately for each user With this setting it can be configured how long the system should ring the user s phone when calling b...

Page 20: ...the image transfer mode supported by the IP camera Stream video continuous content Picture still picture This function works only with cameras that support the ONVIF standard The manufacturer does not...

Page 21: ...rnet access and the outgoing e mail account settings Type open the drop down menu and select the report types which you wish to receive by e mail Event log a full event log can be sent daily or weekly...

Page 22: ...more messages within 24 hours than the number entered here After 24 hours the counter resets automatically thus thereafter incoming messages will be forwarded up to the configured limit number In case...

Page 23: ...input IN1 IN4 is shorted to V terminal DC power negative Special input functions available when using the system with the smartphone application IN1 doorbell notification function via Push notificatio...

Page 24: ...SMS and or e mail upon activating the given input Attention The following characters should not be used Position limit switch OUT1 enabling on input IN3 the gate position limit switch installed on th...

Page 25: ...ing gate A B OUT2 impulse length seconds opening gate B Selective control of outputs OUT1 and OUT2 by using caller identification and by blocking caller ID sending If the caller sends the caller ID ou...

Page 26: ...for X seconds then after W seconds output OUT2 gives open contact for Y seconds then after 1 second output OUT1 gives again closed contact for Z seconds This control mode can be used if the gate cont...

Page 27: ...same user during opening process or opened period during X Y period The gate will close when a third call is received from the same user or a new call from a different user This function cannot be use...

Page 28: ...ed or select it by clicking on the element and then click on the Edit button Enter the element s custom name in the dialog window then click on the Write button Other options export custom names to CS...

Page 29: ...cessary to write them into the module using the Write button erasing the automatic timed control templates deletes all existing automatic timed control templates from the system erasing the access tem...

Page 30: ...ays and user custom rules When this option is selected anyone who sends the caller ID may control the system If the user blocks the caller ID the request for control will be rejected except when contr...

Page 31: ...control modes in case of using control mode 1 or 2 output OUT1 and output OUT2 give permanent closed contact during the interval between the time configured at Open and Close options The automatic ti...

Page 32: ...e by 1 minute but up to 3 messages only Available options read timed control templates from the module add new timed control template edit the selected timed control template delete the selected timed...

Page 33: ...ch user when they can access and control the system Out of the configured entry periods the system rejects the given user s request for control except if this is not overridden by global rule or custo...

Page 34: ...in the configured entry periods and is denied out of the periods If you wish to prohibit entry for a certain day then enter value 00 00 into both time fields of the given day In the Holiday section yo...

Page 35: ...e g 3630 The system accepts maximum 20 digits Accepted characters are 0 9 only Permission you can choose out of three permission levels User can only control the system Admin can control the system an...

Page 36: ...w will receive Technical or device error messages by Push notification when input IN2 is activated If this option is disabled then the smart devices of the given user will not receive technical error...

Page 37: ...y is prohibited for all users except this user who has to work Custom rules are only overridden by the global rule which can be configured in the Admin functions menu Custom rule settings Type None no...

Page 38: ...r Super admin permission then add the client identifier to this user To add a new client identifier manually click the one New button enter the name of the smart device in the Name section of the Clie...

Page 39: ...eriod configured in the Holiday section of the access templates and will be prohibited out of the period The entry permission can be overridden with custom or global rules For the automatic timed cont...

Page 40: ...update the phone number in the settings After replacing the SIM card it is necessary to delete the given module s control button in all smartphone applications assigned and the control button should b...

Reviews: