3.8  Putting into operation 

 

Disable  voicemail  and  notification  in  SMS  about  missed  calls  on  the  SIM  card 
installed into the module. 

 

The  module  can  handle  the  SIM  card’s  PIN  code.  If  you  wish  to  use  the 
PIN 

code  management,  configure  the  SIM  card’s  PIN  code  in  the  programming 

software  at  the 

“Settings”  section.  Otherwise  disable  PIN  code  request  on  the 

SIM card.

 

 

Enable  caller  identification  service  on  the  SIM  card  at  the  GSM  service 
provider

 

(this service might not be enabled by default, please check). To enable this 

service, install the SIM card into a mobile phone and call the customer service of the 
card’s  GSM  service  provider  and  enable  the  service  in  the  menu,  or  visit  one  of  the 
service  provider’s  personal  customer  services  and  ask  to  enable  this  service  on  the 
SIM card. 

  Check the SIM card to be installed correctly into the module. 

  Check the GSM antenna to be connected correctly to the module.  

 

Check the wires to be connected as instructed in the wiring diagram

  You can power up the device (9-30 VAC/DC). 

Make sure that the power source is 

sufficient  for  the  operation  of  the 

Gate  Control  Pro

 

module

The  quiescent 

current of the 

Gate Control Pro

 

module is

 120mA, 

however it may increase up to 

500mA  during  communication  and  relay  control

.  If  the  used  power  source  is  not 

sufficient for the operation of the module, this may cause malfunctions. For such cases 
230VAC/12VDC-1A power adapter can be ordered separately from the manufacturer. 

3.9  LED signals 

Slowly flashing green 

Normal operation, 
connected to GSM network 

Flashing red 

GSM service unavailable 
or system startup/restart in progress 

Permanent red 

SIM card error 

3.10  Technical specification 

Supply voltage range: 

9-30 VAC/DC 

Nominal current consumption: 

120mA 

Highest current consumption: 

500mA @ 12VDC, 250mA @ 24VDC 

Operating temperature: 

-

20ºC - +70ºC 

Transmission frequency: 

GSM  900/1800 MHz 

Highest load supported on outputs:  1A @ 24VAC/DC 
GSM phone model: 

Simcom SIM800F 

Dimensions: 

84 x 72 x 32mm 

Weight: 

200g (packed: 300g) 

Summary of Contents for GSM Gate Control Pro 1000

Page 1: ...caller identification 5 different control modes 4 NO NC inputs 2 NO relay outputs 50 configurable access templates Configurable holidays Automatic timed controls 20 and 1000 user variant Reports the s...

Page 2: ...nfiguring by computer via USB 11 4 3 Configuring by computer over the Internet 11 4 3 1 Adding a client identifier for the programming software 12 4 3 2 Managing SIM identifiers 13 4 3 3 Steps of remo...

Page 3: ...ent permissions and access periods as well as custom access rules can be assigned The access periods can be configured by access templates which can be assigned to users The system will accept control...

Page 4: ...while the position limit switch of gate B should be connected to input IN4 In case of control modes 3 4 and 5 the gate s position limit switch should be connected to input IN3 If the position limit s...

Page 5: ...g on the product type if the supply voltage drops below 8 4 8 2V the module turns off automatically and it turns back on when the supply voltage is at least 11 2 11 4V The minimum supply voltage level...

Page 6: ...tput OUT1 should be connected to input IN3 If two gates are controlled the position limit switch of the gate controlled by output OUT2 should be connected to input IN4 For control modes 3 4 and 5 the...

Page 7: ...d 5 Wiring example for control mode 3 The example shows wiring of inputs IN1 and IN2 when configured to normally open and when inputs IN3 and IN4 are configured to normally closed The example shows wi...

Page 8: ...to open the socket 3 slide the SIM card into the opened part with the contacts facing down as shown in the figure Close back the opened part together with the SIM card Press down carefully the metalli...

Page 9: ...to the module Check the wires to be connected as instructed in the wiring diagram You can power up the device 9 30 VAC DC Make sure that the power source is sufficient for the operation of the Gate C...

Page 10: ...of the installation wizard to complete the installation The latest version of the programming software can be downloaded from the manufacturer s website https tell hu en products gsm automation gsm g...

Page 11: ...d the event log can be downloaded and status information is also available 4 3 Configuring by computer over the Internet For connecting via the Internet the SIM card installed into the Gate Control Pr...

Page 12: ...entifier window then select the Password for remote programming option in the Client identifier section and enter the new password here The software will ask for this password and the user name of the...

Page 13: ...dentifiers button In the SIM identifier editor window you can add new SIM identifiers delete existing ones and change the name and identifier number of existing ones Adding a new SIM identifier To add...

Page 14: ...e Internet green After connecting successfully the settings can be read and changed the event log can be downloaded and the status information can be viewed just like when connected via USB Of course...

Page 15: ...uptime since the last GSM network connection IP uptime the uptime since the last internet connection GSM operator the name of the GSM operator used actually GSM signal actual GSM signal level Lowest...

Page 16: ...ent log to file in CSV format Reading the event log from the module When reading the event log you can specify by filtering options the period and event type you wish to download It is also possible t...

Page 17: ...on Create full system backup You can create a full system backup after clicking on this button The full system backup includes all the settings as well as users database client identifiers templates a...

Page 18: ...ation for backup GSM calls and for SMS sending during the smart device registration process PIN code if you wish to use PIN code management enter here the PIN code of the SIM card installed into the m...

Page 19: ...rol call by calling back the given number Callback option can be enabled separately for each user With this setting it can be configured how long the system should ring the user s phone when calling b...

Page 20: ...the image transfer mode supported by the IP camera Stream video continuous content Picture still picture This function works only with cameras that support the ONVIF standard The manufacturer does not...

Page 21: ...rnet access and the outgoing e mail account settings Type open the drop down menu and select the report types which you wish to receive by e mail Event log a full event log can be sent daily or weekly...

Page 22: ...more messages within 24 hours than the number entered here After 24 hours the counter resets automatically thus thereafter incoming messages will be forwarded up to the configured limit number In case...

Page 23: ...input IN1 IN4 is shorted to V terminal DC power negative Special input functions available when using the system with the smartphone application IN1 doorbell notification function via Push notificatio...

Page 24: ...SMS and or e mail upon activating the given input Attention The following characters should not be used Position limit switch OUT1 enabling on input IN3 the gate position limit switch installed on th...

Page 25: ...ing gate A B OUT2 impulse length seconds opening gate B Selective control of outputs OUT1 and OUT2 by using caller identification and by blocking caller ID sending If the caller sends the caller ID ou...

Page 26: ...for X seconds then after W seconds output OUT2 gives open contact for Y seconds then after 1 second output OUT1 gives again closed contact for Z seconds This control mode can be used if the gate cont...

Page 27: ...same user during opening process or opened period during X Y period The gate will close when a third call is received from the same user or a new call from a different user This function cannot be use...

Page 28: ...ed or select it by clicking on the element and then click on the Edit button Enter the element s custom name in the dialog window then click on the Write button Other options export custom names to CS...

Page 29: ...cessary to write them into the module using the Write button erasing the automatic timed control templates deletes all existing automatic timed control templates from the system erasing the access tem...

Page 30: ...ays and user custom rules When this option is selected anyone who sends the caller ID may control the system If the user blocks the caller ID the request for control will be rejected except when contr...

Page 31: ...control modes in case of using control mode 1 or 2 output OUT1 and output OUT2 give permanent closed contact during the interval between the time configured at Open and Close options The automatic ti...

Page 32: ...e by 1 minute but up to 3 messages only Available options read timed control templates from the module add new timed control template edit the selected timed control template delete the selected timed...

Page 33: ...ch user when they can access and control the system Out of the configured entry periods the system rejects the given user s request for control except if this is not overridden by global rule or custo...

Page 34: ...in the configured entry periods and is denied out of the periods If you wish to prohibit entry for a certain day then enter value 00 00 into both time fields of the given day In the Holiday section yo...

Page 35: ...e g 3630 The system accepts maximum 20 digits Accepted characters are 0 9 only Permission you can choose out of three permission levels User can only control the system Admin can control the system an...

Page 36: ...w will receive Technical or device error messages by Push notification when input IN2 is activated If this option is disabled then the smart devices of the given user will not receive technical error...

Page 37: ...y is prohibited for all users except this user who has to work Custom rules are only overridden by the global rule which can be configured in the Admin functions menu Custom rule settings Type None no...

Page 38: ...r Super admin permission then add the client identifier to this user To add a new client identifier manually click the one New button enter the name of the smart device in the Name section of the Clie...

Page 39: ...eriod configured in the Holiday section of the access templates and will be prohibited out of the period The entry permission can be overridden with custom or global rules For the automatic timed cont...

Page 40: ...update the phone number in the settings After replacing the SIM card it is necessary to delete the given module s control button in all smartphone applications assigned and the control button should b...

Reviews: