3.4.1 Wiring diagram
System terminal inputs and outputs:
V+
Supply voltage 9-30 VAC/DC (min. 500mA)
V-
Supply voltage negative (if DC)
IN1
Dry contact input 1
IN2
Dry contact input 2
IN3
Dry contact input 3
IN4
Dry contact input 4
OUT1
Relay output 1 (normally open dry contact)
OUT2
Relay output 2 (normally open dry contact)
Wiring example for control modes 1, 2, 4, and 5:
Wiring example for control mode 3:
The example shows wiring of inputs
IN1 and IN2 when configured to
normally open, and when inputs IN3
and IN4 are configured to normally
closed.
The example shows wiring of inputs
IN1 and IN2 when configured to
normally open, and when inputs IN3
and IN4 are configured to normally
closed.
When using control mode 3, output
OUT1 is used for control while OUT2 is
used with normally closed state to
interrupt the photocell detection circuit,
thus making it possible to keep the
gate/barrier open for the configured
period of time.