56050801 - Rev B
18
© 2017 Telguard
Troubleshooting Quick Reference Table
Telguard Event
LED Indication
Relay
Output
Radio
Message
Internal Action
STC
Telguar
d System
Trouble
Conditi
ons
ACFC
AC LED off. STC
LED 2
flashes continuously 1
time.
Option
al
None
Switch to standby
battery if present,
monitor battery,
monitor AC for
restoral.
LBC
STC
LED 2
flashes cont.
2 times
.
Option
al
None
Wait for LBC restoral,
charge battery.
NSC
STC
LED 2
flashes cont.
4 times.
Option
al
None
Continue to validate
signal strength, NSC
will restore when
signal returns.
RFC
STC
LED 2
flashes cont.
5 times
.
Option
al
None
Wait for RFC restoral.
DTF -
Dial Tone
Failure
STC
LED 2
flashes cont.
6 times
.
Yes
Yes
Internal
30V
supply
circuit failure.
PPF
STC
LED 2
flashes cont.
7 times.
No
Yes
Wait for PPF restoral.
Not Activated
Activation
LED 1 off.
Yes
None
The Telguard will not
function until the
first signal is sent
through the Telguard
to activate the unit
Automatic Self-Test
Radio
LED 5 flashes
during transmit.
None
Yes (Self-
test)
Send Self-test
information to central
station via TCC,
return to ready state.
Telguard Remote Query
– Communication
Center Activated by
Customer Service.
Radio
LED 5 flashes
during transmit.
None
Yes (Status
data)
Send Status data to
the TCC for review
customer service.
Telguard Enable and
Configuration Upload
–
Radio
LED 5 flashes
during transmit.
None
Configurati
on Data
(Setup
data)
The Telguard sends
setup configuration to
the TCC and switches
to READY state to
begin operation.
Disable TX –
Communication Center
initiated.
Radio
LED 5 flashes
when
transmitting.
Yes
Yes (Status
data)
TX capability is
disabled until further
notice.
The Telguard
can still receive
radio signals from the
TCC.
Note:
If several trouble conditions are present, the STC LED will flash all of the