56050801 - Rev B
14
© 2017 Telguard
Jack Assignments
Jack
Connects To
Pin Assignment
Function
Status LED
Reference
Black
(J13)
Digital Dialer
input/output
of host alarm
panel.
1 = Brown R1
2 = Blue
4 = Green R
(Ring)
5 = Red T (Tip)
7 = Orange
8 = Gray T1
Connects alarm
panel to the
Telguard for
transmitting alarms
to central station.
If PPF is
ENABLED, STC LED
2
will flash 7
times when alarm
panel is not
detected and PPF
enabled.
Main Terminal Strip Pin Assignments
Termina
l Strip
Pin
Definition
Connects
To
Function
Status
LED
Referenc
e
1 STC2
2 STC2
Supervisory Relay
Trip output for
programmable
trouble conditions.
Normally Closed.
24-hour
trip zone
input on
alarm
panel.
Enables transmission of
programmed supervisory trouble
code (see diagram or installation
section).
STC LED
2
3 STC1
4 STC1
Supervisory Relay
Trip output for
programmable
trouble conditions.
Normally Open.
24-hour
trip zone
input on
alarm
panel.
Enables transmission of
programmed supervisory trouble
code (see diagram or installation
section).
STC LED
2
5 GND
Trip Ground
External
trip
relay.
Allows an external relay to
trigger an alarm signal.
6 IN
Trip Input
External
trip
relay.
Allows an external relay to
trigger an alarm signal.
DC Terminal Strip Pin Assignments
Termina
l Strip
Pin
Definiti
on
Connects To
Function
Note
1 GND
2 DC
DC Power
input
12VDC Power
Source
Powers up the
unit
DC power up should not be paired
up with AC or battery
connections.
A/C Terminal Strip Pin Assignments
Termin
al
Strip
Pin
Definiti
on
Connects To
Function
Status LED Reference
1 AC
2 AC
AC power
input.
12 VAC
10VA.
120 VAC 60Hz
un-switched
circuit.
Provides primary
operational power
to the Telguard
and battery
charging circuit.
AC Power LED ON
when AC is normal.
AC power LED OFF
And
STC LED 2
Flashes 1 time when AC is low.